Figure 4-3
The following wire jumpers are set by default:
Wire jumper
1
2
Note
If the wire jumpers are missing, the electronic weighing system reports a wire break.
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Cable shield of the signal cable connected to shield terminal
From terminal
EXC-
EXC+
4.3 Connection of analog load cells
SHIELD
SENSE-
EXC-
SIGNAL-
SENSE+
EXC+
SIGNAL+
To terminal
SENSE-
SENSE+
Connecting
SENSE-
EXC-
SIGNAL-
SENSE+
EXC+
SIGNAL+