Replacing the Power Supply Front Fan — Quantum Ultra 610
The largest (front) fan cools the power supplies. If this power supply fan fails, you can
order a new one from
fan is hot-swappable, that is, it can be replaced while the Quantum Ultra is operating,
without the need to power down the unit.
ATTENTION:
1.
Quantum Ultra Videowall Processing System • Maintenance — Quantum Ultra 610 Only
Remove the front and rear panels from the replacement power supply by
unfastening the three screws on the front and back panels. (These panels and screws
are no longer needed.)
Attach the front plate that was removed from the failed redundant power supply in
step 2 to the three holes on the back panel of the replacement power supply. Use the
three round-headed screws that also were removed in step 2.
Attach the metal strip from the failed power supply to the three holes on the front of
the replacement power supply, using the three flat-headed screws removed in step 3.
steps 6 through 10
Perform
beginning on page 84.
www.extron.com
When a fan fails, replace it immediately. Do not run the unit for a long period
without a fan.
Lorsqu'un ventilateur cesse de fonctionner, remplacez-le immédiatement. Ne
prolongez Pas le fonctionnement de l'unité sans ventilateur.
Use a screwdriver to loosen the two thumbscrews on the cover panel and remove the
panel (see figure 84).
Loosen the thumbscrews.
Take off the panel.
Figure 84.
Removing the Cover Panel
of the primary power supply replacement procedure,
and replace it as described in this section. This