Cleaning the
Air-Conditioning Coil
Service Interval: Every 50 hours Clean the
air-conditioning coil more
frequently in extremely dusty
or dirty conditions.
1. Perform the pre-maintenance procedure; refer
to
Preparing the Machine for Maintenance (page
45).
2. Lift the 4 tabs on the air-conditioning screen
(Figure
81) and remove the screen from the top
of the cab.
Figure 81
1. Screen
3. Disconnect the plug and cord for the fans from
the outlet
(Figure
2
1
Figure 82
1. Knob (2)
2. Fan (2)
4. Remove the 2 knobs that secure the fan-panel
assembly and fans to the underside of the cab
top
(Figure
82) and remove the assembly.
1
2. Tab (4)
82).
3
4
3. Fan panel
4. Plug and cord (2)
5. Clean the screen, air-conditioning duct, fans,
and fan panel using low-pressure air no greater
than 276 kPa (40 psi).
Important:
the condenser because moisture on the
components attracts dirt and dust, which
make the components more difficult to clean.
6. Install the fan-panel assembly and fans to the
underside of the cab top with the 2 knobs that
you loosened and removed in step 4.
7. Connect the cord for the fans that you
disconnected in step
8. Install the air-conditioning screen in the opening
in the top of the cab and secure it by closing the
4 tabs on the screen.
2
g033067
g033067
g033068
g033068
63
Do not use water to clean
3
into the outlet.