speed, adjust the stop bolt in; to decrease the
reverse speed, adjust the stop bolt out.
Hydraulic System
Maintenance

Hydraulic System Safety

Ensure that all hydraulic-fluid hoses and
lines are in good condition and all hydraulic
connections and fittings are tight before
applying pressure to the hydraulic system.
Keep your body and hands away from pinhole
leaks or nozzles that eject high-pressure
hydraulic fluid.
Use cardboard or paper to find hydraulic leaks.
Safely relieve all pressure in the hydraulic
system before performing any work on the
hydraulic system.
Seek immediate medical attention if fluid
is injected into skin. Injected fluid must be
surgically removed within a few hours by a
doctor.
Checking the Hydraulic
System
Service Interval: Before each use or daily
The reservoir is filled at the factory with
approximately 17 L (18 US qt) of high-quality tractor
transmission/hydraulic fluid. The recommended
replacement fluid is as follows:
Toro Premium Transmission/Hydraulic Tractor
Fluid (Available in 19 L (5 gallon) pails or 208 L (55
gallon) drums. See the Parts Catalog or your Toro
Distributor for part numbers).
Alternate fluids: If the Toro fluid is not available,
Mobil® 424 hydraulic fluid may be used.
Note:
Toro will not assume responsibility for damage
caused by improper substitutions.
Note:
Many hydraulic fluids are almost colorless,
making it difficult to spot leaks. A red dye additive for
the hydraulic system oil is available in 20 ml (2/3 fl oz)
bottles. One bottle is sufficient for 15 to 22 L (4 to 6
US gallons) of hydraulic fluid. Order Part No. 44-2500
from your authorized Toro distributor.
1. Park the machine on a level surface, release the
traction pedal to the N
the engine.
2. Run the engine at the lowest possible speed to
purge the system of air.
Important:
Do not engage the PTO.
60
position, and start
EUTRAL