Procedure
Step 1.
Touch the static-protective package that contains the new riser card to any unpainted surface on
the outside of the server. Then, take the new riser card out of the package and place it on a static-
protective surface.
Step 2.
Prepare your server.
1. Power off the server.
2. Remove the top cover. See "Remove the top cover" on page 392.
3. If your server comes with an air baffle, remove it first. See "Remove the air baffle" on page 149.
4. Record all the cables that are passing through the cable wall brackets and disconnect them .
Then, remove any of the following components that are installed on the system board and put
them in a safe, static-protective place.
• "M.2 module" on page 234
• "RAID super capacitor modules" on page 291
• "Middle drive cage" on page 242
• "Rear drive cage" on page 320
• "Backplanes" on page 181
Step 3.
Remove the cable wall brackets.
Figure 52. Cable wall brackets removal
a.
Remove the two screws.
b.
Lift up the brakets from the system board as shown.
After you finish
1. Connect any cables. See Chapter 3 "Internal cable routing" on page 57.
2. Complete the parts replacement. See "Complete the parts replacement" on page 397.