COMMISSIONING
Name
[Maximum water capacity]
[Minimum water capacity]
[Water probe bottom position]
[Upper reference level]
Name
[Water probe length]
[High High alarm]
[High Alarm]
[Low Alarm]
[Low Low alarm]
[Alarm test enable]
134
Water Level
☛
The following entities must be set by Engauge or HART
SmartView for a correct functioning of the FII-VT module in an
instrument.
Explanation
The maximum capacity
when the probe is fully
submerged in water (in pF)
The minimum capacity
when the probe is not
submerged in water (in pF)
The offset to the water
probe zero point in relation
with the tank zero point
The distance from tank zero
point to upper reference
point; is used for water
ullage calculation
☛
The following entities can be set by Engauge or HART
SmartView for a correct functioning of the FII-VT module in an
instrument.
Explanation
The length of the 765 VITO
water probe
4 thresholds for activating a
related alarm status in the
Primary Value
Enables (if activated, see
next listed entity) the
simulation of one of the 4
alarms for a minute, by
simulating the actual
measured Primary Value is
below or above the alarm
threshold.
Service Manual
954 SmartServo FlexLine
Value Range
floating point number:
<-x.x .. +x.x>
floating point number:
<-x.x .. +x.x>
floating point number:
<-x.x .. +x.x>
floating point number:
<-x.x .. +x.x>
Value Range
floating point number:
<-x.x .. +x.x>
floating point numbers:
<-x.x .. +x.x>
<enable>
<disable>
Part No.: 4417340 Revision 1
Default
<20000>
<20000>
<80>
<80>
Default
<0.5>
<+1.0E22>
<disable>