Power Supply Installation
Power-Supply Module Installation
Figure 45
Power-Input Terminal
100-240V~, 50-60Hz, 2A
1
3
5
6
1
Line connection for high-voltage AC (PSU1)
2
Neutral connection for high-voltage AC (PSU1)
3
Positive connection for high-voltage DC
(PSU1)
4
Negative connection for high-voltage DC
(PSU1)
5
PSU1 (power-supply module 1)
6
Positive connection for low-voltage DC (PSU1)
7
Negative connection for low-voltage DC
(PSU1)
Note:
The power-supply module 1 connection is labeled PSU1, and the power-supply module 2 connection is
labeled PSU2. Make sure that you connect the wires to the correct terminal screws.
3.
Use twisted-pair copper wire (14- to 18-AWG) to connect from the power-input terminal to the power source.
Note:
Use 12-AWG (minimum) for the low-voltage DC power supply module. Use 16-AWG (minimum) for the
high-voltage AC or DC power supply module.
4.
Strip each of the two wires to 0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm).
Note:
Do not strip more than 0.27 inch (6.8 mm) of insulation from the wire. Stripping more than the recommended
amount of wire can leave exposed wire from the connector after installation.
Figure 46
Stripping the Input Power Source Wire
0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)
5.
Insert the wire into a spade terminal, and crimp it to the wire.
100-240V~, 50-60Hz, 2A
2
8
4
10
5
2A
7
13
10A
9
11
5
2A
12
14
10A
8
Line connection for high-voltage AC (for
PSU2)
9
Neutral connection for high-voltage AC
(PSU2)
10
Positive connection for high-voltage DC
(PSU2)
11
Negative connection for high-voltage DC
(PSU2)
12
PSU2 (power-supply module 2)
13
Positive connection for low-voltage DC
(PSU2)
14
Negative connection for low-voltage DC
(PSU2)