Switch Installation
Installing the Switch
Installing the Switch
Rack-Mounting, page 19
Wall-Mounting, page 30
If the switch is wall-mounted in an enclosure, follow these minimum clearances:
Sides of switch (facing up and facing down): 3.75 in. (9.52 cm)
Port side 3.0 in. (7.62 cm)
Power supply side: 5.25 in. (13.33 cm)
Cover side (side not facing wall): 1.75 in. (4.44 cm)
Base side (facing wall): 0 in. (0 cm)
Rack-Mounting
To rack-mount the switch, select the rack size and follow the steps in these sections:
Attaching Brackets for 19-Inch Racks, page 19
Attaching Brackets for 19-Inch Racks for IP-30 Compliance (Optional), page 21
Attaching Brackets for 23-Inch Racks, page 27
Attaching Brackets for ETSI Racks, page 28
Rack-Mounting the Switch, page 28
.
Warning:
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to
ensure your safety:
Warning:
For mounting railway-application equipment and for EN50155 standard compliance, the switch must be
installed only in a rack mid-mounting position. If you install the switch in a front rack-mounting (cable side or power
supply side) position or in a wall-mounting position, a mechanical failure can occur that results in the switch
becoming detached from the rack. Statement 403
Attaching Brackets for 19-Inch Racks
Figure 10 on page 20
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with
the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or
servicing the unit in the rack.
and
Figure 11 on page 21
Statement 1006
show how to attach brackets to the switches.