PIAGGIO Beverly 125 Service Station Manual page 149

Hide thumbs Also See for Beverly 125:
Table of Contents

Advertisement

Beverly 125
Refitting
- Check there are no signs of wear on the oil pump
shaft or body.
- Check there are no signs of scoring or wear on
the oil pump cover.
- If you detect non-conforming measurements or
scoring, replace the faulty parts or the unit.
- Fit the pump cover in the position that permits the
crankcase fixing screws to be aligned.
- Make sure the gasket is positioned properly and
refit the pump on the engine crankcase. The pump
can only be fitted in one position. - Tighten the
screws to the prescribed torque.
- Fit the sprocket wheel with a new O-ring.
- Fit the chain.
- Fit the central screw and the belleville washer.
Tighten to the prescribed torque.
- Fit the oil pump cover by tightening the two
screws to the prescribed torque.
N.B.
FIT THE BELLEVILLE WASHER SO THAT ITS OUTER RIM
TOUCHES THE PULLEY. MAKE SURE THAT THE PUMP
TURNS FREELY.
Locking torques (N*m)
Screws fixing oil pump to crankcase
pump control crown screw
er screws
0.7 ÷ 0.9
Oil
5 - 6
Oil pump cov-
10 ÷ 14
Engine
ENG - 149