Optional Fan Kit Installation - Regency Greenfire GF1500L Series Owners & Installation Manual

Hide thumbs Also See for Greenfire GF1500L Series:
Table of Contents

Advertisement

OPTIONAL FAN KIT INSTALLATION

FAN DUCT EXTENSION KIT
1. Attach the connecting collar to the duct that came with the duct kit.
Use the screws provided.
WIRING DIAGRAM
Caution: Ensure that the wires do not touch any hot surfaces
and are away from sharp edges.
Alternate Switches: May use the following. Check with local authorities and electrician.
CLIPSAL 203 2E45 OUD - Dimmer
CLIPSAL 2031 VF3CSF - 3 Speed
919-592
In order to use the fan extension duct kit, you must have
fan kit. This kit allows you to extend the fan duct to 9m.
2. Attach the 4.5m duct within this kit to the connecting collar on the opposite
end with the screws provided. Extend the fl ex to the desired length.
3
Black: High Speed
Greenfield® G1500L Gas Fireplace
GF1500
installation
CAUTION: Label all wires prior to dis-
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation
Red: Low Speed
15.September.15
|
39