WIRING DIAGRAM (NG ONLY)

DISCONNECT POWER SUPPLY TO UNIT PRIOR
TO WORKING ON ELECTRICAL COMPONENTS.
240 v a.c., 50 Hz, 0.8 A.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
845 S.I.T. VALVE
DESCRIPTION
1) On-Off Solenoid Valve EV1
2) On-Off Solenoid Valve EV2
Part #:
3) Inlet Pressure Test Point
4) Outlet Pressure Test Point
5) Connection for Pressure Regulator/Combustion
Chamber Compensation
Size:
6) Pressure Regulator for Minimum and Maximum
Outlet Pressure
7) Gas Outlet Pressure Electric Modulator
Color:
8) Pilot Outlet
9) Main Gas Outlet
909-404 (in-house decal)
(File at 100%)
Black on white
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue flame or
close for a more yellow flame.
Minimum Air Shutter Opening:
NG
18mm
Propane Full Open
ULPG
Full Open
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.