installation
GF1500

OPTIONAL FAN KIT INSTALLATION

NOTE: Installation of Fan Kit should be done prior
to installation of the wall.
2) Mount and secure the fan housing assembly to
framing members, the front of the fan housing will
protrude 12.7mm out of the wall so it may be fi nished
with drywall, etc. See diagram 2
3. Install the air duct run. Secure the duct to the duct
collar on the unit and the fan housing with 3 screws
per end and aluminum duct tape.
Diagram 1:
Front View
Diagram 2: Side View - Secure fan housing
to minimum 45mm framing.
Round Air Duct: Attach the 152.4mm round air duct
(supplied) to the fi replace collar and run the duct to
the fan housing. Attach the round-to-oval adapter
to the fan housing and the air duct to the adapter
4. Install the On/Off switch in a convenient location.
This switch controls the fan operation.
NOTE: Variable speed or Rotary 3 speed switch
can be fi tted.
5. Wire up the the fan, wall switch and power supply
per local codes. See wiring diagram as reference.
*Electrician to supply wiring.
6. Screw fan junction box to the fan housing.
919-592
32
Air Duct
Round to Oval
45mm
7. Screw the Register Adapter Frame and the
Air Register to the Fan Housing See diagram 4.
Diagram 4
8) Remove the knock out on the top of the unit. Cut
away the insulation in a circular motion. Remove
the second knock out, that is below the layer of
insulations.
Fan Housing
Adapter
Secure with 3 Screws and
Aluminum Duct Tape at Unit
9) On the top of the unit, bend the 3 tabs up. Insert the
Duct collar. Secure the collar to the 3 tabs with screws.
Remove the knock out
Cut the insulation
2
Cut the 2nd knock out
Bend the tabs upwards
Duct collar secured
with screws
10) You are now ready to attach fan duct to the unit.
Slide the ducting over the collar and secure with
screws.
11) Final step is to double check the fan ducting
connections at both the unit and fan. Next ensure
there is a minimum of 25mm clearance to combus-
tibles. Strap and secure the fan duct. Double check
the operation of the fan and all electrical work is
completed.