installation
Minimum pressure: Remove one of the orange cables connected to the
electric modulator. While holding the nut (B) with a wrench, screw in the
screw (C) to increase the pressure and screw it out to decrease it. Use
a suitable screwdriver.
After carrying out all adjustments, block the setting screws with paint,
taking care not to obstruct the breather orifice of the pressure regulator.
Put the plastic modulator cap back on.
WARNING: To ensure correct operation of the modulator, return the plastic
cap (A) to its original location.
NOTE: The minimum outlet pressure must be set to 1.6 kPa.
Propane / ULPG Wiring Diagram
240 v a.c., 50 Hz, 0.8 A.
920-195b
36
|
Greenfield® G1500L Gas Fireplace
28. At the end of all setting and adjustment operations, check elec-
trical installation and gas leaks.
29. Check operation of flame control.
30. Check for proper flame appearance and glow on logs.
Installer Notice:
These instructions must be
left with the appliance.
3
GF1500L-1
909-404
06/05/20