Regency greenfire GF900C-NG1 Owners & Installation Manual

Hide thumbs Also See for greenfire GF900C-NG1:
Table of Contents

Advertisement

Quick Links

Greenfire
Gas Fireplace
www.regency-fire.com.au
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Installer: Please complete the details on the back cover and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-500b
GF900C
®
Owners &
Installation Manual
MODELS: GF900C-NG1
GF900C-LPG1
GF900C-ULPG1
GF900C Video
LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS4553 / NZS5262 /
NZS5266 and have been certified by the
Australian Gas Association for installation
and operation as described in these
Installation and Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
01 February 2016

Advertisement

Table of Contents
loading

Summary of Contents for Regency greenfire GF900C-NG1

  • Page 1 Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person. www.regency-fire.com.au WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas:...
  • Page 2 The control box will only learn the Remote ID codes during the first 30 seconds after power is applied and will ignore this special command from the Remote after the first 30 seconds Note: The pairing up process can be carried out by anyone. Note: In addition; please also go to: www.regency-fire.com.au to see the pairing up video. Regency GF900C-1 Gas Fireplace...
  • Page 3: Table Of Contents

    Unit Installation with Horizontal Termination ....25 Electronic components parts list ........44 4" x 6-5/8" (102mm x 175mm) flueing ......25 Main Assembly ............45 Unit Installation with Horizontal Termination ....26 Accessories ..............47 Unit installation with Vertical Termination .....27 Warranty ..............50 Regency GF900C-1 Gas Fireplace...
  • Page 4: Copy Of Data Badge

    Colour: Black on Grey Size: 100% 7" W x 2.7" H Aug.02/12 - draft for approval. Dec. 20/12: Approved - added AGA # Jan.21/13: Rev. A: Updated consumption #’s Dec. 23/13: Updated E. Aus address (Australia Only) Regency GF900C-1 Gas Fireplace...
  • Page 5: Unit Dimensions

    DIMENSIONS UNIT DIMENSIONS (76mm) (259mm) (500mm) (560mm) (14mm) (1091mm) (522mm) (995mm) (1082mm) (889mm) (795mm) (536mm) (332mm) (725mm) (160mm) (113mm) (1192mm) (989mm) Verona Surround Faceplate Dimensions Regency GF900C-1 Gas Fireplace...
  • Page 6: Important Message

    9) Wear gloves and safety glasses for protection while doing required maintenance. 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. Regency GF900C-1 Gas Fireplace...
  • Page 7: Installation Checklist

    9) Final check. Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer. Diagram 1 Flat on Wall Corner Recessed into Wall/Alcove Corner Regency GF900C-1 Gas Fireplace...
  • Page 8: Clearances

    Note: 0" No hearth required television. See clearance requirements for both mantle (page 9) and or enclosing the top of the appliance (Page 11 D dimensions). Installed Close Installed close to Floor to ceiling. Alcove Regency GF900C-1 Gas Fireplace...
  • Page 9: Mantel Clearances

    (502mm) (667mm) Nailing Flange (254mm) (438mm) To Unit Base Top of Fireplace (610mm) Opening MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 83mm Non-Combustible MANTEL LEG 38mm 181mm Allowable mantel leg projection 254mm 330mm Regency GF900C-1 Gas Fireplace...
  • Page 10: Unit Assembly Prior To Installation

    3) Install any optional components with access panel removed. 4) Reinstall access panel by lining up 2 upper tabs, then secure with 4 screws . Note: Access panel is no longer usable once facing material installed. Installation Access Panel Regency GF900C-1 Gas Fireplace...
  • Page 11: Framing Dimensions

    NOTE: A minimum thickness of 12mm non-combustible facing board is required. Drywall or other facing Header Note: All framing may Non-Combustible be of wood construction. Facing NOTE: Do not place timber/steel studs below the timber framing studs Timber already in place. Studs Finished Floor Regency GF900C-1 Gas Fireplace...
  • Page 12: Non Combustible Facing Installation

    The finishing of the walls surrounding age to board. The non combustible board must be a minimum Regency is as critical as the installation itself. The temperatures around of 12mm thick. Material which is thinner may crack as a result linear gas fireplaces are typically higher than would be acceptable for the due to the high temperatures this appliance emits.
  • Page 13: Framing & Finishing

    The faceplate will not be able to be mounted if finished material is beyond 1-1/2" (38mm). 1002mm Unit shown with inner door frame only Ensure front of facing mate- rial is flush with the edge of the flange on the fireplace. Regency GF900C-1 Gas Fireplace...
  • Page 14: Framing & Finishing

    1-1/2" (38mm) edge of the flange. 1-1/2" 0" (flush) 38mm Nailing Strip Flush w/unit Factory Set Unit NON-COMBUSTIBLE REQUIREMENTS Header on edge 1165mm Timber Stud Timber Stud Non-combustible Material NOTE: A minimum thickness of 12mm non-combustible facing is required Non-combustible 83mm Regency GF900C-1 Gas Fireplace...
  • Page 15: Exterior Flue Termination Locations

    (IV) A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved. Regency GF900C-1 Gas Fireplace...
  • Page 16: 4" X 6-5/8" (102Mm X 175Mm) Rigid Pipe

    SV4PF Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com Regency GF900C-1 Gas Fireplace...
  • Page 17 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 18: Flue Restrictor Position

    4. Adjust the flue restrictor plate to the required flue restrictor position as per the diagrams shown below. 5. Once the flue restrictor plate is in the required position, secure with screws. Set 3 - 15mm open Set 2 - 18mm open Set 1 - 26mm open Set 0 - 64mm Open Regency GF900C-1 Gas Fireplace...
  • Page 19: Flueing Introduction

    Refer to the "Flue Restrictor Position" section for details on how to change the flue restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Flue Flex System may be used for installations with a maximum continuous flue length of up to 3m.
  • Page 20: Horizontal Terminations

    S.S. screws #8 x 1-1/2” drill point Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be ® used for Flex installations 3) Horizontal flue must be supported every 0.9m.
  • Page 21: Horizontal Terminations

    Metal Products Ameri Flue Direct Flue, Security Secure Flue , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Flue® and Direct Flue are registered and/or proprietary trademarks of Simpson Dura-Flue Co. Inc. Regency GF900C-1 Gas Fireplace...
  • Page 22: Horizontal Terminations

    • Flex system can only be used up to 3m - otherwise rigid flueing must be used. Straight Out Horizontal Flueing Diagram 1 center of hole Please note the minimum centerline for basic install shown above. Regency GF900C-1 Gas Fireplace...
  • Page 23: Vertical Terminations

    Metal Products Ameri Flue Direct Flue, Security Secure Flue , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Flue® and Direct Flue are registered and/or proprietary trademarks of Simpson Dura-Flue Co. Inc. Regency GF900C-1 Gas Fireplace...
  • Page 24: Flueing Arrangement For Vertical Terminations

    Restrictor Set #3 on how to change the flue restrictor from the factory 15mm open setting of Set 0 to Set 1 or Set 2 if required. "THIS UNIT MUST ALWAYS TERMINATE / FLUE DIRECTLY TO THE OUTDOORS." Regency GF900C-1 Gas Fireplace...
  • Page 25: Unit Installation With Horizontal Termination

    3 supplied screws (drilling pilot holes will make this easier). 4) Level the fireplace and fasten it to the framing using nails or screws through the top and side Diagram 2 nailing strips. Diagram 7 Regency GF900C-1 Gas Fireplace...
  • Page 26: Unit Installation With Horizontal Termination

    Apply Mill Pac Outer Diameter) or high temperature silicone to the outer flex pipe and slip it over the outer flue collar of the flue terminal at least 1-3/8"(35mm) and fasten with the 3 screws. Regency GF900C-1 Gas Fireplace...
  • Page 27: Unit Installation With Vertical Termination

    Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the flue height may solve the problem. Regency GF900C-1 Gas Fireplace...
  • Page 28: High Elevation

    NOT covered under warranty. Note: Screw should be snug, but do not over NOTE: A shutoff / dante valve should be tighten. supplied in or near the unit (or as per local codes) for ease of servicing this appliance. Regency GF900C-1 Gas Fireplace...
  • Page 29: Wiring Diagram

    BLUE Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency GF900C-1 Gas Fireplace...
  • Page 30: For Gf900 Using Sit 845 Nova Gas Valve

    3. Remove burner side panels by lifting out as shown in Diagram 1. 6. Remove glass crystals and stones, if installed. 7. Remove 3 screws in locations shown below to remove burner tray. Diagram 1 - Burner Side Panels Diagram 4 - Burner Tray Screw Locations Regency GF900C-1 Gas Fireplace 05/05/14 919-131a...
  • Page 31 18. Reverse steps 17, 16, 15, 9, for both units. For GF900C reverse Steps 8-6 and Step 1. For GF900L reverse steps 5-1. 19. Adjust the air shutter opening (See page 28 for Aeration Adjust- ment) 20. Turn on gas supply and plug in power cord. Regency GF900C-1 Gas Fireplace 919-131a 05/05/14...
  • Page 32 23. At the end of all setting and adjustment operations, check electri- cal installation and gas leaks. 24. Check operation of fl ame control. 25. Check for proper fl ame appearance and glow on logs. Installer Notice: These instructions must be left with the appliance. 05/05/14 919-131a Regency GF900C-1 Gas Fireplace...
  • Page 33: Glass Crystals And Volcanic

    PROPANE UNIT NOTE: Volcanic Stones are NOT to be placed anywhere on the burner or Pilot assembly area on Propane Units. Ensure air gap around burner is not obstructed by the placement of the stones. Regency GF900C-1 Gas Fireplace 10/29/12 919-198...
  • Page 34: Inner Panel Removal / Installation

    1. Install the optional finishing trim by lining up trim with the outside of the fascia. Press trim inward firmly to seat onto the unit. Note: magnets will keep the trim in place. tooltip Finishing Trim Installed 2. Pull trim outward–away from the unit to remove. Regency GF900C-1 Gas Fireplace 11.05.15 919-615...
  • Page 35: Faceplate & Deflector Installation

    4. Remove any finger prints/ marks prior to operating the unit. WARNING: Turn off the unit by way of the wall switch or remote. Allow unit to cool at least 10 min. - prior to Diagram 3 removing the faceplate. Regency GF900C-1 Gas Fireplace 11.17.15 919-616...
  • Page 36: Screen & Inner Door Frame Installation

    Diagram 1 2. Bend Tab on Screen Mesh to 90º as shown in Diagram 2. Secure to Diagram 3 Inner Door Frame with one (1) screw as shown in Diagram 2a. Diagram 2 Diagram 2a Regency GF900C-1 Gas Fireplace...
  • Page 37: Operating Instructions

    OUT THE GLASS FRONT IN PLACE. low setting. LIGHTING REMOTE CONTROL INSTRUCTIONS Use the Regency Remote Control Kit approved FAN OPERATION for this unit. Use of other systems may void 1) Plug the power cord into a power outlet. your warranty.
  • Page 38: Copy Of Lighting Plate Instructions

    Blower: below the inner door frame. supplier. Regency gas appliances use high tech blowers A) BEFORE LIGHTING smell all around the appliance to push heated air farther into the room. It is not 2) Wait for approximately 3 seconds - the area for gas.
  • Page 39: Fan Service

    9. Remove two (2) screws to remove fan shown in Diagram 6. Diagram 2 - Burner Screw Locations 5. Remove air deflector by removing 3 screws in locations shown below. Diagram 6 - Fan Screws Diagram 3 - Air Deflector Screw Locations Reverse steps to reinstall fan. Regency GF900C-1 Gas Fireplace...
  • Page 40: Maintenance Instructions

    7. Verify operation after servicing. WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person. Regency GF900C-1 Gas Fireplace...
  • Page 41 Providing the pressure switch has continuity and convection fan is creating pressure,the electrode should spark and the gas valve open within 5 seconds of the completion of the purge cycle. Regency GF900C-1 Gas Fireplace...
  • Page 42: Glass Door Installation

    6. Pull the bottom of the door towards you until the door is angled away from the firebox by about 30°. Lift the door up and over the upper door hooks. 7. To install the glass door - reverse steps. Regency GF900C-1 Gas Fireplace...
  • Page 43: Valve Tray Replacement

    Diagram 5 - Valve Tray Removal Replace valve tray and reverse steps. Diagram 2 - Burner Screw Locations 5. Remove air deflector by removing 3 screws in locations shown below. Diagram 3 - Air Deflector Screw Locations Regency GF900C-1 Gas Fireplace...
  • Page 44: Electronic Components Parts List

    911-121 Ignition Module (2) 910-514 Jumper Wire      910-935 Manual Control Switch     **Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 Regency GF900C-1 Gas Fireplace...
  • Page 45: Main Assembly

    Remote Control 911-101 Control Box 911-121 Ignition Control Module 911-112 Pressure switch 911-113 Switch On/Off w/Cat 5 cable 910-155/P Blower Motor 911-161 Black Reset Button 466-063 Valve mounting bracket 466-104 Valve access plate Not Shown 919-500 Manual Regency GF900C-1 Gas Fireplace...
  • Page 46: Parts List

    PARTS LIST MAIN ASSEMBLY Regency GF900C-1 Gas Fireplace...
  • Page 47: Accessories

    Inner door frame - Stainless w/ Screen 33 467-544 Door Frame Overlay - Black 34 467-938 Fascia and Door Frame Black w/Screen 467-936 Fascia and Door Frame Stainless Steel w/Screen 35 467-951 Fascia Black Glass (not shown) Regency GF900C-1 Gas Fireplace...
  • Page 48 NOTES Regency GF900C-1 Gas Fireplace...
  • Page 49 NOTES notes Regency GF900C-1 Gas Fireplace...
  • Page 50: Warranty

    ® Regency shall in no eflue be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products. SUBJECT TO CHANGE.
  • Page 51 07 849 7585 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency GF900C-1 Gas Fireplace...
  • Page 52 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency is a registered trademarks of FPI Fireplace Products International Ltd. GF900C Video © Copyright 2015, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Greenfire gf900c-lpg1Greenfire gf900c-ulpg1

Table of Contents