Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certified by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
GFI300L Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
an authorised installer, service agency or
the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
919-293b
Models:
GFI300LNG-R
GFI300LLP-R
GFI300LULPG-R
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any phone
in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas
supplier, call the fire depart-
ment.
Nov. 25/14

Advertisement

Table of Contents
loading

Summary of Contents for Regency GFI300LNG-R

  • Page 1 Owners & Installation GFI300L Gas Inbuilt Models: GFI300LNG-R GFI300LLP-R GFI300LULPG-R PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, alteration, What to do if you smell gas: service or maintenance can cause injury or Do not try to light any appli- property damage.
  • Page 2 GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by Regency Industries. The Regency Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model GFI300L of this series has been approved by Australian Gas Association for both safety and efficiency.
  • Page 3: Table Of Contents

    Optional Enamel panels ..........17 Burner and pilot Assembly ...........33 Log Set installation ............18 Glass door installation ..........21 Warranty Faceplate & trim installation ........22 Primary Glass guard installation ........23 Warranty ..............35 Optional mesh guard installation .........23 Wiring ................24 Regency GFI300L Gas Fireplace Inbuilt...
  • Page 4: Copy Of Data Label

    INSTALLATION DATA BADGE NOTE: Regency units are constantly This is a copy of the label that accompanies being improved. Check the label on the unit and each Regency GFI300L Gas Inbuilt fireplace. We have printed a copy of the contents here if there is a difference, the label on the unit is the for your review.
  • Page 5: Unit Dimensions

    INSTALLATION UNIT DIMENSIONS 683 mm 908mm 100 mm 288 mm flue 236mm 362mm Regency GFI300L Gas Fireplace Inbuilt...
  • Page 6: For Your Safety

    Electrical: 240 volt 50 hz system Fan/Blower: 3-speed CHECKLIST Log Sets: Ceramic fibre The Regency Gas Insert is installed as listed below. BEFORE YOU START 1) Unit Location - check Clearances to Combus- tibles. Installation is to be carried out ONLY by an authorised person.
  • Page 7: Minimum Fireplace Dimensions

    The below minimum cavity requirements are to be maintained to ensure safe and proper operation of the appliance. Ensure all construction conforms to local building codes. MASONRY INSTALLATION: The minimum fireplace dimensions for a masonry installation are shown in the diagrams below. 688mm 238mm 125mm 367mm Regency GFI300L Gas Fireplace Inbuilt...
  • Page 8: Mantel Leg Clearances

    INSTALLATION MINIMUM CLEARANCES TO 6" 12" (152mm) (305mm) COMBUSTIBLES The minimum fireplace clearances for the Regency gas space heater are 26" shown in the following diagrams: (660mm) From Unit Sides A 464 mm 12" (305mm) Ceiling B 860 mm 20"...
  • Page 9: Mock Fireplace Dimensions

    56" (1422mm) Gas Connection Opening Height 2" (51mm) Gas Connection Height 2-5/8" (67mm) Gas Connection Inset 3-11/16" (99mm) Gas Connection Opening Width 2-1/2" (64mm) Note: All framing may be of wood construction. Timber Studs Finished Floor Regency GFI300L Gas Fireplace Inbuilt...
  • Page 10: Optional Mock Fireplace Installation

    Diagram 1 Diagram 3 Note: Side brackets can be adjusted between 13 mm to 38 mm. This adjustment must be done before unit is moved into framed opening. Diagram 2 Diagram 4 Regency GFI300L Gas Fireplace Inbuilt...
  • Page 11: Framing & Finishing

    3) Finishing material may be brought to the side and top of the framing. do not bring combustible material beyond the framed opening. This is both for safety and servicing of the appliance. Finished Wall Unit shown with Fascia Framed Opening 800mm Regency GFI300L Gas Fireplace Inbuilt...
  • Page 12: Appliance Gas Connection

    Injector Size 2.50mm 1.50mm 1.30mm Input Max. 30 Max. 27 Max. 21 Rating Min. Min. 22 Min. 17 20mj Manifold 0.9 kPa 2.3 kPa 2.3 kPa Pressure Aeration 5 mm 13 mm full Setting open Regency GFI300L Gas Fireplace Inbuilt...
  • Page 13: Draft Diverter Connection

    A minimum flue height of 0.6 m. is required for Diagram 2. masonry applications. The Regency Inbuilt Fireplace For wind turbulent sites, a wind cap may remedy incorporates its own internal draft diverter, so no the problem.
  • Page 14: Gas Line Installation

    Minimum Air Shutter Opening: 3/16" (5mm) 1/2" (13mm) ULPG Full Open Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 15: Conversion Kit To Lp Or Ulpg

    - slide to the right and lift up and out to remove and discard 12. Remove burner orifice with a 1/2" wrench and discard. Use another wrench to hold on to the elbow below the orifice. Loosen Remove Regency GFI300L Gas Fireplace Inbuilt...
  • Page 16 All the adjustments must be carried out in the following order: 24. Check operation of flame control. 25. Check for proper flame appearance and glow on logs. Installer Notice: These instructions must be left with the appliance. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 17: Optional Enamel Panels

    4) Before installing the side panels, loosen the screws for the tabs enough so that you can slide the tabs on to the screws easily but that the tabs are secure. For the location of the side tab screws see diagram 2. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 18: Log Set Installation

    3. Place Log 3 on the centre of the burner, rest the log against the centre tabs. Logs 1 - fi ts over pins behind burner Logs 3 - place in centre of Logs 1 - in position burner, resting against tabs 05/08/14 919-332a Regency GFI300L Gas Fireplace Inbuilt...
  • Page 19 5 mm 5 mm gap between Logs 3 & 4 Log 6 fi ts in notch on Log 1 5 mm MPORTANT Maintain a 5mm gap between Logs 3 & 4 919-332a 05/08/14 Regency GFI300L Gas Fireplace Inbuilt...
  • Page 20 8. Log 8 will cover pilot assembly, resting on pilot assembly bracket and trim of the burner tray as shown below. Log 8 covers Pilot Assembly MPORTANT Ensure Log 8 is centered over Pilot Assembly. Failure to do so will cause improper burning. 05/08/14 919-332a Regency GFI300L Gas Fireplace Inbuilt...
  • Page 21: Glass Door Installation

    2. Once in position, slide glass door down and secure with 2 screws at the bottom of the door as shown below, and tighten the top 2 (two) screws. 3. To remove- reverse steps. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 22: Faceplate & Trim Installation

    2 screws as shown below. 2. Lift Faceplate over brackets on top of unit - hook faceplate over brackets and lower gently. 5. Proceed to glass or optional mesh guard installation. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 23: Primary Glass Guard Installation

    INSTALLATION PRIMARY GLASS GUARD INSTALLATION 1. Insert silicone grips into all four (4) glass retaining brackets. 2. Slide glass through brackets. OPTIONAL MESH GUARD INSTALLATION Regency GFI300L Gas Fireplace Inbuilt...
  • Page 24: Wiring

    Do not cut or remove the earthing prong from operation. Caution: Ensure that the wires do not this plug. touch any hot surfaces and are away from sharp edges. * Ground = Earthing Regency GFI300L Gas Fireplace Inbuilt...
  • Page 25: Operating Instructions

    REMOTE CONTROL FAN OPERATION INSTRUCTIONS Use the Regency Remote Control Kit approved Set the fan speed on the control panel to adjust 1) Plug the power cord into a power outlet. for this unit. Use of other systems may void to the desired speed.
  • Page 26: Copy Of Lighting Plate Instructions

    For Blower: assistance or additional information consult side of the fascia. Regency gas appliances use high tech blowers a qualified installer, service agency or gas supplier. to push heated air farther into the room. It is not 3) Press and release the reset button - once.
  • Page 27: Maintenance Instructions

    & reinstalled in accordance with the manufacturer's instructions. WARNING: Do not operate the appliance with the glass 8) Verify operation after servicing. panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 28: Valve Tray Replacement

    9. Remove burner - loosen screw on left side, remove screw from right side - slide to the right and lift up and out to remove. 12. Replace valve tray and reverse steps 11-1. Loosen Remove Regency GFI300L Gas Fireplace Inbuilt...
  • Page 29: Fan Maintenance

    4. Slide fan forward and lift out to remove. 4. Slide switch out to the left side. 5. Remove switch and replace. 6. Reverse steps to complete installation. Wingnuts 5. Replace or service fan. 6. Reverse steps 5-1 to reinstall fan. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 30: Gas Pressure

    THE MOST IMPORTANT ITEM TO CHECK DURING THE INSTALLATION AND THE FIRST THING TO CHECK WHEN PROB- LEMS OCCUR IS GAS PRESSURE. Regency GFI300L Gas Fireplace Inbuilt...
  • Page 31: Main Assembly

    Wire Jumper SIT ignition module 904-345 Burner Orifice #53 LPG 910-080 Sigma Valve NG 904-575 Burner Orifice #55 ULPG 910-081 Sigma Valve LP 911-145 Manual Switch 919-293 Manual Not shown Not shown Not a replacement part Regency GFI300L Gas Fireplace Inbuilt...
  • Page 32 PARTS LIST MAIN ASSEMBLY Regency GFI300L Gas Fireplace Inbuilt...
  • Page 33: Faceplate Assembly

    PARTS LIST FACEPLATE ASSEMBLY Part # Description 940-428/P Tempered Glass 948-066 Glass Standoff (ea) BURNER AND PILOT ASSEMBLY Part # Description 911-146 Pilot Assy NG 911-157 Pilot Assy LP Regency GFI300L Gas Fireplace Inbuilt...
  • Page 34 NOTES Regency GFI300L Gas Fireplace Inbuilt...
  • Page 35: Warranty

    Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 36 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Gfi300llp-rGfi300lulpg-r

Table of Contents