Installing A Tv/Artwork Flush With The Unit - Regency Greenfire GF1500L Series Owners & Installation Manual

Hide thumbs Also See for Greenfire GF1500L Series:
Table of Contents

Advertisement

INSTALLING A TV / ARTWORK FLUSH WITH THE UNIT
Note: All wiring should stay free and clear of the vent system to avoid damage due to heat, if located directly in front of the vent system.
Ensure wiring is secured without any sag.
Heat deflector must overhang front of TV by 51mm.
Follow mantel clearance chart for install height and heat deflector depth.
A—Depth of TV & Mounting Bracket
127mm
153mm
178mm
203mm
229mm
A
C
B
13mm Air Gap
Note: The TV mounting bracket can not be secured directly to the appliance. It must be secured to framing. The TV depicted in the picture may need to be
higher depending on the style of TV mounting bracket used. The mounting bracket shown is a simple single strip TV secured to framing.
B—Height From Base of Unit
981 mm
1006 mm
1029 mm
1052 mm
1077 mm
51mm
L
C—Distance From Top of 13mm Air Gap
351 mm
376 mm
399 mm
422 mm
446 mm
installation