Dust Collection

DO NOT operate your jointer without an ade-
quate dust collection system. This machine
creates substantial amounts of wood dust
while operating. Failure to use a dust collec-
tion system can result in short and long-term
respiratory illness.
Recommended CFM at Dust Port: 400 CFM
Do not confuse this CFM recommendation with
the rating of the dust collector. To determine the
CFM at the dust port, you must consider these
variables: (1) CFM rating of the dust collector,
(2) hose type and length between the dust col-
lector and the machine, (3) number of branches
or wyes, and (4) amount of other open lines
throughout the system. Explaining how to cal-
culate these variables is beyond the scope of
this manual. Consult an expert or purchase a
good dust collection "how-to" book.
To connect a dust collection hose:
1.
Fit 5" dust hose over dust port, as shown in
Figure 20, then secure it in place with hose
clamp.
Dust
Hose
Figure 20. Dust hose attached to dust port.
2.
Tug hose to make sure it does not come off.
Note: A tight fit is necessary for proper
performance.
-20-
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The Troubleshooting table in the
SERVICE section of this manual can help.
The Test Run verifies that safety features stop
the machine when needed, and that the machine
operates properly prior to regular operation.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
To test run machine:
1.
Clear all setup tools away from machine.