3M -Matic AccuGlide 2+ 800af Instructions And Parts List page 58

Adjustable case sealer with taping heads
Table of Contents

Advertisement

15 - TROUBLESHOOTING (continued)
Troubleshooting Guide
Problem
Flap kicker kicks at wrong time
Gate does not raise to stop next
box
Gate retracts too soon/kicker does
not kick
Two boxes are taped together
800af-I-NA
Cause
Kicker cam improperly set
Air cylinder fl ow controls out of
adjustment
Too much air pressure on gate
cylinder lifts box off of gate cam
Incoming boxes not low enough
and therefore not actuating cam
The removable portion of the gate
cam has been removed and boxes
shorter than 12 inches are being
run
48
Correction
Reposition kicker cam
Readjust fl ow controls
Reduce gate air pressure using
regulator
Reinstall removable gate cam
portion
2010 December

Advertisement

Table of Contents
loading

Table of Contents