11 - OPERATION (continued)
11.1 - Component Locations (continued)
Air On/Off
Valve
"OFF"
"ON"
Figure 11-3 – "On/Off" Valve/Regulator/Filter
1
Electrical "On/Off" Switch
The box drive belts are turned on and off (off
button is red) with the electrical switch on the
side of the machine guard at the infeed end.
2
Main Air "On/Off" Valve/Pressure
Regulator/Filter – Figure 11-3
This set of pneumatic components controls,
regulates and fi lters plant air supply to the two
separate control circuits of the case sealer.
"On/Off" Valve – "On" turn to "SUP" – "Off" turn to "EXH"
Note – Turning air supply "Off" automatically bleeds
air pressure from the case sealer air circuits.
Always turn the air "Off" when machine is not in use,
when servicing the machine, or when connecting or
disconnecting air supply line.
Note – The air valve has provisions for lockout/tagout
according to plant regulations.
Pressure Regulator regulates main air pressure
to the machine to adjust pressure, pull knob up and
turn – push down to lock setting.
Filter removes dirt and moisture from plant air
before it enters the case sealer pneumatic circuits.
If water collects in bottom of bowl, lift up on the valve
on the bottom of bowl to drain.
3
Emergency "Stop" Switch
The two emergency "Stop" switches are mounted
for operator convenience, on both sides of the case
sealer. Pushing either of these switches will stop
the drive motors/belts and exhaust air from the fl ap
kicker. To restart machine, rotate emergency stop
switch (release switch latch) and then restart ma-
chine by pressing green (On) button on side guard.
800af-I-NA
Up
to
Adjust
Down
to
Lock
Regulator
Filter
28
4
Height Adjustment Crank, Upper
Taping Head
Raises and lowers upper taping head/fl ap
folders to accommodate box height.
5
Width Adjustment Crank
Adjusts distance between side drive belts to
accommodate box width.
6
Top Flap Compression Rollers
Rollers adjust to properly maintain box width/
top fl ap center seam for tape seal. Indicator,
7
Air Pressure
The optical warning indicator, located on the
upper fl ap folder frame, indicates "Red" when
compressed air circuit is on.
8
Box Gate Air Pressure Regulator
Adjusts lifting force of the box gate depending
on the weight of boxes being sealed.
9 Gate Cams - Figure 11-4
The gate cams A
entry into the case sealer. Depending on box
size, gate cams can be adjusted to increase
production rate. See "Adjustments – Gate
Operation".
Kicker Cam - Figure 11-4
10
The minor fl ap folder, controlled by the kicker
cam C , closes the trailing minor fl ap on
C
the box. The kicker cam must be adjusted
according to the length of the box being sealed.
See "Operation".
11 Pocket, Instruction Manual
A pocket is provided inside the right door for
storage of the machine instruction manual.
Keep the manual in this pocket for the
convenience of machine operators.
C
Figure 11-4 – Gate/Kicker Cams
B control the rate of box
B
A
2010 December