F007
Type Reset
Program ⇒ Utilities
This feature assists the user when performing fault analysis or by allowing a
quick system setup change when required. Performing a Type Reset results in
one of the following user-selected post-reset configurations.
Settings:
0 — None
1 — 50 Hz Setting
2 — 60 Hz Setting
3 — Reset to Factory Settings
4 — Clear Past Trips
5 — Clear Run Timer
6 — Initialize Typeform
7 — Save User Settings
8 — Restore User Settings
9 — Clear Cumulative Fan Timer
10 — Accel/Decel Time Setting 0.01 – 600.0 Seconds
11 — Accel/Decel Time Setting 0.1 – 6000.0 Seconds
12 — Update EOI Firmware
13 — Set EOI Memory to Default
14 — Save User Settings to EOI
15 — Restore User Settings from EOI
Forward/Reverse Run Selection
Program ⇒ Fundamental ⇒ Standard Mode Selection
While operating using the keypad
sets the direction of motor rotation. This setting may be changed during
operation. This setting will not override parameter
Disable).
If either direction is disabled via parameter F311, the disabled direction will not
be recognized if commanded by the keypad. If both directions are disabled via
parameter F311, the direction command from the keypad will determine the
direction of the motor rotation.
Settings:
0 — Forward
1 — Reverse
2 — Forward (EOI-switchable F/R)
3 — Reverse (EOI-switchable F/R)
H9 ASD Installation and Operation Manual
(F003
is set to EOI Keypad) this parameter
F311
(Forward/Reverse
Direct Access Number — F007
Parameter Type — Selection List
Factory Default — None
Changeable During Run — No
Direct Access Number — F008
Parameter Type — Selection List
Factory Default — Forward
Changeable During Run — Yes
F008