Demonstrate when JIB is changed JIB reset must be pressed and held to reset light
Demonstrate Auto Top-Off on a vat by moving oil out of vat
AUTOMATIC INTERMITTENT FILTRATION (AIF) – Refer to the LOV Quick Reference Guide
Demonstrate assembly of the filter pan (Emphasize need for daily pad change / more often as needed)
Demonstrate AIF cycle on "TEST" menu item. Air bubbles should only be observed in unit being filtered.
Show Blue LED, SAY "YES" TO THE BLUE LIGHT
Show "FILTER NOW" displayed on vat to be filtered
Demonstrate new skimming procedure
Show filtration issues (OIL TOO LOW, errors created by not changing the pad (monitor oil returned to vat
levels – should be where it started)
Show FILTER BUSY message by trying to manual filter while another vat is filtering.
Six consecutive unsuccessful filtrations and unit goes to SERVICE REQUIRED an authorized technician is
needed.
Show location of thermal reset on Filter Motor
TROUBLESHOOTING
Common error messages
Is Vat Full? – a problem may exist in the filtration system – Follow instructions on the computer.
Drain Clogged- Clear Drain-Is Drain Clear? (Gas Only) – Follow instructions on the computer using
the new fryers friend to clear the drain.
Filter Busy – a filtration process is in another vat
Probe Failure – Temperature circuitry has a problem – Turn off fryer and call for service
Heating Failure – Unit is not heating – Turn off fryer and turn on again.
Low Temp – Oil temperature below set point – may occur during cooking cycle
Recovery Fault – Vat did not meet minimum specs for temperature recovery – Press the
continue.
Service Required – a problem exists that requires a technician.
Frymaster's Hot line and ASA contact person / with phone numbers
Refer to LOV Quick Reference Guide and Operations Manual Chapter 4
Demonstrate daily cleaning of the oil sensor during maintenance filters with no-scratch pad (gas only).
FILTER MENU (Press and hold LEFT or RIGHT FLTR button based on the type of vat being filtered)
NON BULK OIL SYSTEM
Demonstrate how to access FILTER MENU
Show AUTO FILTER and explain what it does
Show MAINT FLTR (always filter the Fish vat last)
Show DISPOSE and explain what it does (Use of MSDU)
Show DRAIN TO PAN and explain what it does
Show FILL VAT FROM DRAIN PAN and explain what it does
BULK OIL SYSTEM
Demonstrate how to access FILTER MENU
Show AUTO FILTER and explain what it does
Show MAINT FLTR (always filter the Fish vat last)
Show DISPOSE and explain what it does
Show DRAIN TO PAN and explain what it does
Show FILL VAT FROM DRAIN PAN and explain what it does
Show FILL VAT FROM BULK and explain what it does
Show PAN TO WASTE and explain what it does