WATTS
7000
7000
7000
8500
8500
8500
11000
11000
11000
Improper element wiring: The fryer elements
contain separate wires (two for each phase).
Improper wiring connections will cause one or
more of the following symptoms:
• Slowly rising or creeping fryer temperature.
• Improper amperage draw.
• Slow Recovery.
• Over heating
Defective
elements:
internally cause several symptoms, which are
similar to incorrect element wiring. These
elements must be replaced; they cannot be
repaired.
When the fryer is on, an element with
two phases connecting internally will heat
continuously. Use an amp meter on the element
wires to determine which phases are shorted.
Perform the check when the fryer is not calling
for heat.
When an element shorts to the chassis or element
housing, it heats continuously when the fryer is on.
An amp meter will identify the line drawing current.
Check when the fryer is not calling for heat.
Electric Fryers
VOLTAGE
208V
240V
480V
208V
240V
480V
208V
240V
480V
Elements
shorted
Element wiring connections.
3-9
OHM TOLERANCE
16.8 – 19.5 Ω
22.4 – 25.9 Ω
89.6–103.7 Ω
13.9 – 16.0 Ω
18.4 – 21.3 Ω
73.0 – 85.2 Ω
10.7 – 12.4 Ω
14.3 – 15.8 Ω
57.0 – 66.0 Ω
1 2 3
H-SERIES AMP DRAW
Voltage
14kW
208
39
240
34
480
17
220/380
21
230/400
21
240/415
20
4 5 6
17kW
22KW
48
61
41
53
21
27
26
34
25
32
24
31