LOV/FQ Error Codes
CODE
ERROR MESSAGE
M3000 ONLY
E01
REMOVE DISCARD (Right)
M3000 ONLY
E02
REMOVE DISCARD (Left)
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E07
ERROR MIB SOFTWARE
E08
ERROR ATO BOARD
E09
ERROR PUMP NOT FILLING
E10
ERROR DRAIN VALVE NOT OPEN
E11
ERROR DRAIN VALVE NOT CLOSED
E12
ERROR RETURN VALVE NOT OPEN
E13
ERROR RETURN VALVE NOT CLOSED Return valve failed to close; valve's position is unknown.
E14
ERROR AIF BOARD
E15
ERROR MIB BOARD
E16
ERROR AIF PROBE
E17
ERROR ATO PROBE
E18
Not Used
E19
CAN TX FULL©
E20
INVALID CODE LOCATION
FILTER PAD/PAPER PROCEDURE ER-
E21
ROR (Change Filter Pad or Paper)
E22
OIL IN PAN ERROR
E23
CLOGGED DRAIN (Gas)
OIL RETURN (level) SENSOR FAILED
E24
(Gas)
E25
RECOVERY FAULT
M3000 ONLY
E26
RECOVERY FAULT CALL SERVICE
E27
LOW TEMP ALARM
FilterQuick3000 ONLY
E28
HIGH TEMP ALARM
Automatic Filtering Fryers
A product cook is started on the right side of a split vat or in
a full vat that has a different setpoint other than the current
vat temperature.
A product cook is started on the right side of a split vat or in
a full vat that has a different setpoint other than the current
vat temperature.
TEMP Probe reading out of range.
High limit reading is out of range.
High limit temperature is more than 410°F (210°C), or in
CE countries, 395°F (202°C).
A component has failed in the high limit circuit such as
controller, interface board, contactor or open-high limit.
Internal MIB software error.
MIB detects ATO board connection lost; ATO board failure.
Oil not returning to vat quickly. Possible problems: dirty
pad, bad or missing O-rings, tripped or defective fi lter
pump, actuators or linkage.
Drain valve failed to open; valve's position is unknown.
Drain valve failed to close; valve's position is unknown.
Return valve failed to open; valve's position is unknown.
MIB detects AIF missing; AIF board failure.
Cooking controller detects MIB connections lost; check
software version on each controller. If versions are missing,
check CAN connections between each controller; MIB
board failure.
AIF RTD reading out of range.
ATO RTD reading out of range.
Connection between controllers lost.
SD card removed during update.
25 hour timer has expired or dirty fi lter logic has activated.
The MIB has detected oil may be in the pan.
Vat did not empty during fi ltration.
Oil return sensor may have failed.
Recovery time exceeded maximum time limit.
Recovery time exceeded maximum time limit for two or
more cycles.
Oil temperature has dropped lower than 15°F (8°C) in idle
mode or 45°F (25°C) in cook mode.
Oil temperature has risen 40°F (22.2°C) higher than
setpoint. If temperature continues to rise, the high limit
will shut the power off at 425°F (218°C) Non-CE or 395°F
(202°C) CE.