Error Log Codes
To access the error log, press the home button. Press the service button. Press the manager button. Enter 1656 and
press the check button. Press the E-log button. The ten most recent errors are listed from top to bottom, with the top
error being the most recent error. A "G" indicates a global error such as a filtration error. Side-specific errors in split
vats are indicated by L for left or R for right. Pressing the left down arrow allows scrolling through the errors. If no
errors are present the screen will be blank
Code
ERROR MESSAGE
E13
TEMPERATURE PROBE FAILURE
E16
HIGH LIMIT 1 EXCEEDED
E17
HIGH LIMIT 2 EXCEEDED
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
E19
HEATING FAILURE – XXX F or XXX C
E25
HEATING FAILURE - BLOWER
E27
HEATING FAILURE - PRESSURE SWITCH - CALL SERVICE
E28
HEATING FAILURE – XXX F or XXX C
E29
TOP OFF PROBE FAILURE - CALL SERVICE
E32
DRAIN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E34
RETURN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E35
RETURN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E36
VALVE INTERFACE BOARD FAILURE - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E37
AUTOMATIC INTERMITTENT FILTRATION PROBE FAILURE
- FILTRATION DISABLED - CALL SERVICE
E39
CHANGE FILTER PAD
E41
OIL IN PAN ERROR
E42
CLOGGED DRAIN (Gas)
E43
OIL SENSOR FAILURE - CALL SERVICE
E44
RECOVERY FAULT
E45
RECOVERY FAULT – CALL SERVICE
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL SERVICE
E51
DUPLICATE BOARD ID - CALL SERVICE
E52
USER INTERFACE CONTROLLER ERROR - CALL SERVICE
E53
CAN BUS ERROR - CALL SERVICE
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL SERVICE
E62
SLOW HEATING FAILURE XXXF OR XXXC - CHECK ENERGY
SOURCE - CALL SERVICE
E63
RATE OF RISE
E64
FILTRATION INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL SERVICE
E66
DRAIN VALVE OPEN – XXXF OR XXXC
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED - CALL
SERVICE
Touchscreen-Equipped Fryers
.
TEMP Probe reading out of range
High limit temperature is past more than 410°F (210°C), or in
CE countries, 395°F (202°C)
High limit switch has opened.
Vat temperature exceeds 460°F (238°C) and the high limit has
failed to open. Immediately disconnect power to the fryer
and call service.
Heating Control latch circuit failed.
Heat Contactor failed to latch.
The air pressure switch(s) failed to close.
The air pressure switch has failed closed.
The fryer has failed to ignite and has locked out the ignition
module.
ATO RTD reading out of range
Drain valve was trying to open and confirmation is missing
Drain valve was trying to close and confirmation is missing
Return valve was trying to open and confirmation is missing
Return valve was trying to close and confirmation is missing
Valve Interface Board connections lost or board failure.
AIF (VIB Probe) RTD reading out of range.
25-hour timer has expired or dirty filter logic has activated.
The system detects that oil may be present in the filter pan.
Vat did not empty during filtration
Oil level sensor may have failed.
Recovery time exceeded maximum time limit.
Recovery time exceeded maximum time limit for two or more
cycles.
-> SERVICE ->3000-> TECH MODE -> RESETS -> RECOVERY
FAULT CALL SERVICE -> YES.
SIB board 1 connection lost or board failure.
Two or more controllers have the same location ID.
The controller has an unknown error.
Communications are lost between boards.
SIB board 2 connection lost or board failure.
The vat is not heating properly.
Rate of rise error occurred during a recovery test.
Filtration Interface Board connections lost or board failure.
Gas -The oil is back sensor does not detect oil. Clean optional
oil sensor.
Drain valve is opened during cooking.
Controller is turned on when the SIB board is not configured.
5-17
EXPLANATION
Reset the error code by going to: HOME -> SERVICE

Advertisement

loading

This manual is also suitable for:

Ocf seriesFilterquick seriesLov series