Th e FQ4000 Controller Introduces Fryer Connectivity
Data on the fryer's use is collected on the circuit
boards, consolidated by the Smart Interface Board and
passed over the bus to the SUI board, located in the
Filter Interface Board box.
Th e data is then transfered, via the store's wireless
router or a cellular router, to an internet-based dash-
board hosted on a server. Store management can mon-
itor oil usage, how frequently the staff responds to fi lter
Touchscreen-Equipped Fryers
24VDC
OQS
SIB1
C Bus
requests, cook cycles and store-level fryer management.
Successful communication from the fryer can be
determined from the Soft ware Version screen of the
controller, where signal strength and the IP address can
be seen (see below).
NOTE: The end-of-line re-
sister is a component of the
SUI in fryers with wireless
communication.
End of Line
Resister
5-15
Data fl ow from the
End of Line
SUI to the store's
Resister
wireless to a cloud
server and then on
to an analytic com-
puter display.
C Bus
Successful communica-
tion from the fryer can be
determined at the Software
Version screen on the
controller, where the signal
strength and the IP address
can be seen.
An antenna on the
exterior of the FIB
is the connection to
the store's wireless.
Caps on either side of
the antenna provide
access to LAN and
USB ports.