Download Print this page

Frymaster H55 Series Technical Reference Manual page 117

Advertisement

Use Controller's Version, Component Check Features for Diagnostics
Two features in the controller make checking on the presence and performance of components in the network
easy. Navigating to the soft ware version window allows temperature comparison between the ATO and the tem-
perature probe. A dramatic diff erence indicates a probe problem or an oil level problem.
Navigating to the Component Check window, allows relays to be opened/closed, latch relays to be checked,
blower motors to be run.
Use Soft ware Display for Diagnostics
Press the Home button
Press the Question Mark button.
Press the down arrow to navigate to the
Software version icon.
Press the software icon.
Press the down arrow to scroll the software
versions for each component: SIB, FIB,
VIB, SUI, OQS, etc.
The numbers should match current version
numbers.
The absence of numbers or the presence
of all zeros in a component fi eld means
that component is not being seen on the
network.
Scroll with the down arrow again to the
temperature display for the ATO and the
temperature probe.
The numbers should be very close. A big
difference indicates a probe issue or an oil
level problem.
Use Error Codes to Track Problems
Press Home button.
Press Service button.
Press Manager button.
Enter 1656
Press check mark.
Scroll recorded error codes with up and
down arrow keys.
The codes are displayed, in the order they
were recorded, in windows of three.
There's a video guide to responding to error
codes included on the fl ash drive.
Error codes can point to operational issues,
such as failure to fi lter, that lead to required
maintenance.
Touchscreen-Equipped Fryers
How to Use Component Check Feature
See Error
Code Log,
Pages 5-17,
5-18
5-14
5 14
Turn the fryer off.
Press the Home button.
At the Crew Mode screen, press the Service
icon.
Press the Service Man Icon.
Enter 9-0-0-0 on the keyboard.
Press the check mark.
Tap Tech Mode.
Navigate to the Component Check screen and
press the button.
The controller populates with buttons for fryer
components.
Turn the components on and off as necessary
to check component function. Listen closely
for relays to open and close.
Be careful opening drain valves and running
pumps. There are no safeties in diagnostic
mode.
Draining to Pan/Filling From Pan
When a repair, such as a
probe replacement, requires
draining a vat, the controller is
used to move the oil to the fi l-
ter pan. Follow the steps below
to drain the aff ected frypot.
Press the Filter button.
Select vat (if split) to drain from display.
Scroll to Drain to Pan and select it.
Press check mark.
Ensure the fi lter pan is fully inserted.
Press Blue button to start draining.
Insert Pan is displayed if pan is not fully in place.
Draining is followed by Vat Empty.
Tap Yes when the vat is empty.
Follow prompts to return oil to vat when work is
fi nished.

Advertisement

loading

This manual is also suitable for:

Ocf seriesFilterquick seriesLov series