5. Troubleshooting
Message
"Cannot import."
"The file is blank."
"Cannot import."
"Enter the IP address in singlebyte
characters."
"Cannot import. The IP address
format is invalid."
"Cannot import. The format of the
IP address is incompatible."
"Up to 100 addresses can be
added."
"The first 100 addresses in the file
have been imported."
126
Cause
The import file is empty.
Lines with full-width characters
entered in the IP address exist
in the import file.
Lines with an inaccurate format
of IP address exist in the import
file.
Lines with inaccurate values of
IP address exist in the import
file.
101 or more connection
destinations are set to the
import file.
Solution
Check the contents of import
file.
Check whether lines with full-
width characters entered in the
IP address exist in the import
file.
Check whether there is any
applicable item in the
following conditions for an
import file.
• IP address is blank.
• IP addresses are not half-
width digits within 3 digits
consisting of four portions
divided by periods.
• The value of the half-
width digits within 3 digits
consisting of four portions
divided by periods is
inaccurate.
• The number exceeding
256 exists.
• The number which starts
with 0 or 00 exists.
Check whether IP addresses
(0.0.0.0, 127.0.0.1, etc.)
used for a specific use are set
in the import file.
Make the connection
destinations set to the import
file less than 100.