LMV Series
Typical LMV52 System for a Cleaver Brooks Retrofit
Components for a typical LMV52 retrofit on a Cleaver Brooks boiler are listed below:
Control Panel Components
1
LMV52.240B1
1
AGG5.210
1
AZL52.40B1
1
AGG5.635
1
AGG5.720
1
AGG5.110
2
BR-LMV5
Air Damper Assembly
1
SQM48.497B9
1
BR-48CBAIR
Gas Firing Rate Control Valve
1
VA45.2-NF-300
Oil Firing Rate Control Valve
1
SQM45.295B9
1
BR-45CBOIL
Actuator Accessories
1
AGG5.643(100)
1
ADP-M16XE500(5)
1
ADP-M16XE500-LONG(5)
Flame Scanner
1
QRI2A2.B180B
Flame Scanner Accessories
1
AGG2.110
1
AGG2.120
Sensors
1
7MF1565-4BE00-5EA1
1
QAC22
1
QAM-P210
Variable Frequency Drive (VFD) Components
1
AGG5.305
O
Trim Components
2
1
PLL52.110A100
1
QGO20.000D17
1
AGO20.002LDS-KT
1
C8120(35)
SCC Inc.
Dual fuel burner control, fuel-air ratio control, VFD control, O
120 VAC to (3) 12 VAC transformer
Display with Modbus port, PC port, six languages available
Pre-made 9 foot cable connecting an LMV5 to the AZL display
Base plug set with all terminals for a typical LMV5 system
Strain relief and actuator CANbus grounding
Brackets for mounting an LMV5 in an electrical enclosure
Actuator, 177 in-lb torque, 14mm keyed shaft, 30-120 sec running time
CB air damper bracket retrofit kit for SQM48 actuator
SQM45.295B9 to 3" full port VKG butterfly valve assembly
Actuator, 27 in-lb torque, 10mm "D" shaft, 10-120 sec running time
CB fuel oil controller bracket retrofit kit for SQM45 actuator
100' roll of CANbus cable
5-pack of M16 to 1/2" NPSM metal conduit adapters
5-pack of long M16 to 1/2" NPSM metal conduit adapters
Self-check infrared flame scanner, forward viewing
Kit for mounting forward viewing QRI... flame scanner on a flame tube
Pg9 to 1/2" NPSM conduit connection adapter for QRI... flame scanner
Pressure sensor, 0-30 PSI, 4-20 mA signal
1000 Ohm, 2-wire, nickel RTD for ambient air temperature
1000 Ohm, 2-wire, platinum RTD for flue gas temperature
Speed sensor and associated mounting kit for VFD control
CANbus module to connect QGO O
O
sensor with zirconium dioxide measuring cell
2
Weldless flue gas collector for stacks 18-36" in diameter
6-conductor shielded cable to connect the O
Page 19