Host connection (SAS Port)
Configuration 3:
Configuration 3 allows up to two redundantly configured hosts to view a specific zone group of drives.
Each host will be able to view up to 51 drives that are mapped to both IOMs. Each zone group will display
all of the devices that are contained within that zone. If a drive slot is not populated, it will still be part of
that zone group, but it will not display any results in enclosure management until the drive slot has been
populated. In this Configuration, the enclosure is divided into two zone groups as shown in the image
below represented by two different colors. Each zone group matches to three SAS ports on each side of
the rear IOM to allow for the connections to two different hosts.
• In-band management: Configuration 3 can be initiated in the sg_senddiag command in-band by
using 03 in the Zoning Configuration option. See:
senddiag commands.
• Out-of-band management: Configuration 3 can be initiated in the out-of-band management by using
3 in the ZoningConfig option. The following are example Redfish POST and cURL commands:
Figure 221: Configuration 3
Enclosure IOM connection (SAS Port)
Host 2
Host 2
Host 2
Host 3
Host 3
Host 3
Host 3
sg_senddiag Command (page 205)
5. System Management
A4
B3
B4
A5
A6
B5
B6
for the actual
5.3 Zoning