Table 44: Procedure Info
Required Tools
Long T15 Torx
Screwdriver
# 2 Philips Screwdriver
Long T10 Torx
Screwdriver
Cable Ties (for
configurations
with greater than
10 total cables)
Tape Measure
Step 1 : Place the CMA(s) into service position.
a. Unlatch the CMA(s) from the rail at the elbow connector by pressing the blue release
button.
b. Swing the CMA(s) away from the enclosure.
c. The arm(s) should be extended away from the enclosure as shown in the following
example.
Reuse: M5 x 12mm T15
Flat Head Torx screws
Reuse:Included Washers
Low-Profile M4 x 3.2mm
Philips screws (included
8mm T10 Torx screws
Level
Figure 99: Unlatching a CMA Connector
Required Parts
with rail assembly)
Optional (if using
CMA Tray): M3 x
4. Part Replacement
4.8 Rails Replacement
# of People Required Time Required
3 Total (2 for Team
Lifting Purposes and
1 to Guide and Spot)
~1h