Servicing The Pneumatic System; Adjusting The Operating Pressure - DURKOPP ADLER 867 Service Instructions Manual

Hide thumbs Also See for 867:
Table of Contents

Advertisement

Maintenance

22.3 Servicing the pneumatic system

22.3.1 Adjusting the operating pressure

Proper setting
Refer to the Technical data ( p. 137) chapter for the permissible
operating pressure. The operating pressure cannot deviate by more than
± 0.5 bar.
Check the operating pressure on a daily basis.
Fig. 100: Adjusting the operating pressure
(1) - Pressure regulator
To adjust the operating pressure:
1. Pull the pressure regulator (1) up.
2. Turn the pressure regulator until the pressure gage (2) indicates
3. Push the pressure regulator (1) down.
Service Instructions 867 - 04.0 - 10/2019
NOTICE
Property damage from incorrect adjustment!
Incorrect operating pressure can result in damage to the machine.
Ensure that the machine is only used when the operating pressure
is set correctly.
the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
(2) - Pressure gage
119

Advertisement

Table of Contents
loading

Table of Contents