Code
Type
2121
DA stepper card 1 encoder
plug (Sub-D, 9-pin) not
connected
2122
DA stepper card 1 rotor
position not found
2220
DA stepper card 2 not
responding
2221
DA stepper card 2 encoder
plug (Sub-D, 9-pin) not
connected
2222
DA stepper card 2 rotor
position not found
3103
Low voltage warning
st
(1
threshold)
Mains voltage < 180 V AC
3108
Speed limited due to
insufficient mains voltage
3150
Maintenance necessary
3155
No release for sewing
process
3160
Stitch loosening device
3215
Bobbin stitch counter
(info value 0 reached)
3216
Remaining thread monitor
left
3217
Remaining thread monitor
right
3218
Remaining thread monitor
left and right
3223
Skip stitch detected
3224
Bobbin failed to rotate
6360
No valid data on external
EEprom (internal data
structures are not
compatible with the external
data storage device)
6361
No external EEprom
connected
Troubleshooting
Remedial action
• Connect encoder cable to the control,
use correct connection
• Check connection cables
• Check stepper motor 1 for stiff
movement
• Check connection cables
• Check LEDs of DACextension box
• Software update
• Connect encoder cable to the control,
use correct output
• Check connection cables
• Check stepper motor 2 for stiff
movement
• Check mains voltage
• Stabilize the mains voltage
• Use generator
• Check mains voltage
• Information on lubricating the machine
 Service Instructions
• Parameter t 51 20-t 51 33 = 25
• Input signal for sewing process release
required
• Stitch loosening cannot be performed
• Change bobbin, set counter value
• Press counter reset button
• Change the left bobbin
• Change the right bobbin
• Change the left and right bobbin
• Software update
• Connect machine ID