Henny Penny EVOLUTION ELITE Series Operator's Manual page 91

Reduced oil capacity open fryer
Table of Contents

Advertisement

Display
Cause
"E-60"
AIF PC board not
"FILTER IN
communicating
USE"
with PC board.
"E-70C"
Drain valve jump-
er wire missing or
disconnected.
"E-83-A"
Pressure too
high.
"E-83-B"
Pressure too
high.
"E-83-C"
Pressure too high
"E-83-D"
Pressure too
high.
"E-83-E"
Pressure too
high.
"E-83-J"
Bulk BIB FILL
switch ON when
pressure too
high.
"E-83-R"
Bulk Dispose
switch ON when
pressure too
high.
"E-931"
Autolift motor
"24 VDC
malfunction or
SUPPLY
failure.
TRIPPED"
Panel Board Correction
Turn power switch to OFF, wait 15 seconds, then turn
switch back to ON. If "E-60 persists, have connector be-
tween the PC boards checked; replace AIF PC board or
control PC board if necessary.
Have the jumper wire checked on the PC board at drain
switch interlock position.
Check filter system in Vat #1.
Check filter system in Vat #2.
Check filter system in Vat #3.
Check filter system in Vat #4
Check filter system in Vat #5.
Check BIB fill valves.
Check Bulk Dispose quick-disconnect behind fryer.
If AutoLift feature is not operating, have each of the Auto-
lift motors checked.