Menu Step
SP-8 Filter
Tracking Mode
70
down to the idle set-point temperature. Press the right arrow and "SP-
7C" "IDLE SETPT" flashes in the left display. Press the up or down ar-
row, or use the product buttons, to set idle temperature 200°F to 375°F
(93°C to 191°C).
Filter Tracking signals the operator when the oil needs filtering by count-
ing the number of Cook Cycles between filters.
Press and release the right arrow until "SP-8" "FILTER TRACKING
MODE" shows in the display. Use the up or down arrow to choose either
"1.MIXED" filter tracking or "2.GLOBAL".
NOTE:
•
GLOBAL means all the products have the same number of cook
cycles between filters
•
MIXED means each product may be set with different number of
cook cycles between filters. The controls add the cycle count (see
example below) and when the counts equal 1 or greater, filtering is
suggested. Ex., 1 load of fish. 2 loads of french fries, a load of
chicken equals 1. 1/2 + 1/8 + 1/8 + 1/4 = 1
Product
Fish
French Fries
Chicken
M M I I X X E E D D
If MIXED is selected, press the right arrow and SP-8A" "SUGGEST FIL-
TER AT..." shows in the left display, and a value between 75% and 100
% shows on the right display. Press the up or down arrow to change this
value. The lower the value, the sooner the control recommends to filter.
Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed
cook cycles must be completed before the control suggest filtering. Press
the right arrow and "SP-8B" "LOCKOUT ENABLED?" shows in the left
display. Press the up or down arrow to choose "YES or "NO". If set to
"YES", when controls suggest filtering, "FILTER LOCKOUT"/"YOU
*MUST* FILTER NOW", shows in display; more cook cycles are refused
until vat is filtered. Press the right arrow and "SP-8C" "FILTER LOCK-
OUT AT..." shows in left display and a value between 100% and 250%
shows on right display. Press the up or down arrow to change this value.
The lower the value, the sooner the "lockout" occurs. Ex., If set at 100%,
"lockout" occurs when the cycle count reaches 1 or greater. Set at 200%,
twice as many cycles are counted before "lockout" occurs.
G G L L O O B B A A L L
If GLOBAL is selected, press the right arrow.
•
S S p p l l i i t t V V a a t t
If unit is a split vat, "SP-8A" "LEFT VAT FILTER CYCLES" shows in
left display, and the number of cook cycles between filters shows on
Description
No. Cook Cycles
Cycle Count
2
8
4
1/2
1/8
1/4