Menu Step
SP-8 Filter
Tracking Mode
70
down to the idle set-point temperature. Press the right arrow and "SP-
7C" "IDLE SETPT" flashes in the left display. Press the up or down ar-
row, or use the product buttons, to set idle temperature 200°F to 375°F
(93°C to 191°C).
Filter Tracking signals the operator when the oil needs filtering by count-
ing the number of Cook Cycles between filters.
Press and release the right arrow until "SP-8" "FILTER TRACKING
MODE" shows in the display. Use the up or down arrow to choose either
"1.MIXED" filter tracking or "2.GLOBAL".
NOTE:
GLOBAL means all the products have the same number of cook
cycles between filters
MIXED means each product may be set with different number of
cook cycles between filters. The controls add the cycle count (see
example below) and when the counts equal 1 or greater, filtering is
suggested. Ex., 1 load of fish. 2 loads of french fries, a load of
chicken equals 1. 1/2 + 1/8 + 1/8 + 1/4 = 1
Product
Fish
French Fries
Chicken
M M I I X X E E D D
If MIXED is selected, press the right arrow and SP-8A" "SUGGEST FIL-
TER AT..." shows in the left display, and a value between 75% and 100
% shows on the right display. Press the up or down arrow to change this
value. The lower the value, the sooner the control recommends to filter.
Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed
cook cycles must be completed before the control suggest filtering. Press
the right arrow and "SP-8B" "LOCKOUT ENABLED?" shows in the left
display. Press the up or down arrow to choose "YES or "NO". If set to
"YES", when controls suggest filtering, "FILTER LOCKOUT"/"YOU
*MUST* FILTER NOW", shows in display; more cook cycles are refused
until vat is filtered. Press the right arrow and "SP-8C" "FILTER LOCK-
OUT AT..." shows in left display and a value between 100% and 250%
shows on right display. Press the up or down arrow to change this value.
The lower the value, the sooner the "lockout" occurs. Ex., If set at 100%,
"lockout" occurs when the cycle count reaches 1 or greater. Set at 200%,
twice as many cycles are counted before "lockout" occurs.
G G L L O O B B A A L L
If GLOBAL is selected, press the right arrow.
S S p p l l i i t t V V a a t t
If unit is a split vat, "SP-8A" "LEFT VAT FILTER CYCLES" shows in
left display, and the number of cook cycles between filters shows on
Description
No. Cook Cycles
Cycle Count
2
8
4
1/2
1/8
1/4