Installing a heavy-duty design CSA certified connector. In order to be able to
2 2 ) )
service this appliance, which is provided with casters, a connector complying
with ANSI Z21.69-CAN 6.16 or CAN 1-6.10m88 and a quick-disconnect device,
complying with ANSI Z21.41or CAN 1-6.9m70, must be installed. It must also be
installed with restraining means to guard against transmission of strain to the
connector as specified in the appliance manufacturer's instructions.
See the illustration on the following page for the proper connection of flexible
3 3 ) )
gas line and cable restraint.
NOTE: The cable restraint limits the distance the open fryer can be pulled from the
wall. For cleaning and servicing the unit, the cable must be unsnapped from the open
fryer and the flexible gas line disconnected. This allows better access to all sides of
the open fryer. The gas line and cable restraint must be reconnected once the
cleaning or servicing is complete.