2 2 . . 7 7 G G a a s s L L e e a a k k T T e e s s t t
NOTE: Prior to turning the gas supply on, be sure the gas valve knob on the gas
control valve is in the off position.
Upon initial installation, and after moving the unit, the piping and fittings should be
checked for gas leaks. A simple checking method is to turn on the gas and brush all
connections with a soap solution. If bubbles occur, it indicates escaping gas. In this
event, the piping connection must be redone.