Henny Penny EVOLUTION ELITE Series Operator's Manual page 83

Reduced oil capacity open fryer
Table of Contents

Advertisement

Menu Step
SP-23 Bulk Oil
Press and release the right arrow until "SP-23 BULK OIL DISPOSE?"
Disposal
flashes in the left display. Press the up or down arrow to choose "YES
DISP" or "NO DISP". Set to "YES DISP" if the oil is pumped from the vats
to an outside oil reservoir when discarding the oil. Otherwise, set SP-23
to "NO DISP".
SP-24 Serial
Press and release the right arrow until "SP-24 S/N ✓EDIT" flashes in the
Number Log
displays, along with the serial number of the unit.
NOTE: This serial number should match the serial number on the data
plate, on the doors. If not, it can be recorded.
SP-25 Program
This allows the operator to change the program code (factory set at 1, 2,
Code Change
3) used to access Product Programming and Level 2 Program Mode.
Press and release the right arrow until "SP-25 CHANGE MGR CODE?
1=YES" flashes in the display. Press product 1
CODE" "P=DONE" "I=QUIT" scrolls through the display. Press the prod-
uct buttons for new code. If satisfied with the code, press the program
button
display. Enter the same code you previously entered. If satisfied with
code, press the program button
display. If not satisfied with code, press the info button
CEL*" shows in display, then reverts back to "SP-25" "CHANGE MGR
CODE? 1=YES". Now the above steps can be repeated.
SP-26 Usage
This allows the operator to change the reset usage code (factory set at 1,
Code Change
2, 3) to reset the usage amounts of each product. See
Usage , page 60
Press and release the right arrow until "SP-26 CHANGE USAGE CODE?
1=YES" flashes in the display. Press product 1 and "ENTER NEW
CODE" "P=DONE" "I=QUIT" scrolls through display. Press product but-
tons for new code. If satisfied with code, press the program button and
"REPEAT NEW CODE" "P=DONE" "I=QUIT" shows in the display. Enter
the previously entered code. If satisfied with code, press the program
button
code, press the info button
verts back to "SP-26" "CHANGE USAGE CODE? 1=YES". Now the
above steps can be repeated.
SP-27 Dispose
Press and release the right arrow and "SP-27 DISPOSE REQUIRES
Requires Code?
CODE?" flashes in the left display. Press the up or down arrow to choose
"YES" or "NO". If set to "YES", code 1, 2, 3, must be entered to discard
the oil from the vat using the Dispose Mode.
SP-28 Longer
Press and release the right arrow until "SP-28 LONGER FILL TIME EN-
Fill Time
ABLED?" flashes in the left display. Press the up or down arrow to
choose "YES" or "NO".
Description
and "REPEAT NEW CODE" "P=DONE" "I=QUIT" shows in
and "CODE CHANGED*" shows in
in .
, "*CODE CHANGED*" shows in display. If not satisfied with
and "*CANCEL*" shows in display the re-
and "ENTER NEW
and "*CAN-
4.1.5 5. Review