Proper Lifting Of Sprayer; Initial System Setup - Graco XM Series Operation

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Proper Lifting of Sprayer

Follow instructions to avoid serious injury or damage
to equipment. Never lift with the hopper(s) filled.
To prevent spilling and to ensure even weight
distribution, drain all fluid prior to lifting th
proportioner.
Lift Using a Forklift
Power must be off. Sprayer can be raised and moved
using a forklift. Carefully lift the sprayer; make sure it
balances evenly.
Lift Using a Hoist
Sprayer can also be lifted and moved using a hoist.
Connect a bridle swing, hooking an end to each of the
air motor lift rings. Hook the center ring to a hoist. See
the following figure. Carefully lift the sprayer; make sure
it balances evenly.
2.0 ft. (0.61 m)
minimum

Initial System Setup

Complete the following steps in order, as they apply to
your specific system, for initial system setup.
1. Check your shipment for accuracy. Ensure you have
received everything you ordered. See Component
312359M
NOTICE
Identification, page 14, to familiarize yourself with
typical system components.
2. Mount caster kit, if ordered. See your kit manual.
3. Mount hopper brackets, if ordered. See your hopper
manual.
4. Loosely mount hoppers, if ordered, on brackets.
See your hopper manual.
5. Connect bottom hopper outlet if using a gravity feed
pump. See your hopper manual.
6. Tighten hopper mounting bolts. See your hopper
manual.
7. Mount and connect agitator(s) and feed pump(s), if
ordered. See your hopper manual.
8. Mount and connect hopper immersion heater kit, if
ordered. See your hopper manual.
9. Connect recirculation hose, restrictor valve
(including knob and nipple), and recirculation tube.
Place in hopper or drum. See your hopper manual.
10. Replace USB label (front of control panel) with
correct language version, if needed.
11. Replace Alarms Codes label (under fluid control
valves) with correct language version, if needed.
12. Install hopper/hose heated circulation kit, if ordered.
See manual 313259 for instructions.
13. For non-hazardous location sprayers, connect
power cord (not supplied). See Connect Power
Cord, page 20, for instructions.
14. For non-hazardous location sprayers, connect
junction box wiring for immersion or recirculation
heaters. See your hopper and heater manuals.
15. For hazardous location sprayers, connect
explosion-proof heaters. See Wire Sprayers with
Explosion-Proof Heaters, page 22, and your
heater manual.
16. Connect air supply line. See Connect Air Supply,
page 22, for instructions and recommendations.
17. Connect fluid hose assembly, including whip hose
and gun. See Connect Fluid Hose Assembly,
page 23, for instructions. Also connect remote mix
manifold, if ordered. See your mix manifold manual.
Proper Lifting of Sprayer
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm50Xm70