Troubleshooting - Graco XM Series Operation

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Troubleshooting

XM Setup and Troubleshooting
Guide
The following setup information will help ensure the system
is setup properly. See the XM repair-parts manual for
troubleshooting and repair instructions.
Grounding
Ground system to a true earth ground.
Ensure incoming power is grounded.
Air Supply
Use at least a 3/4 in. (19mm) ID air hose, no longer
than 50 feet (15m).
Ensure the first gauge (supply) stays above 80 psi
(0.55 MPa, 5.5bar) while spraying.
Ensure that the pump spray pressure regulator is set to
at least 35 psi (2.4 bar) for spraying.
Ensure that the solenoid air filter/regulator behind the
air panel is set to at least 80-85 psi.
Check that the air filter element in the solenoid air
filter/regulator behind the air panel is clean.
Calibration
Adjust the B side fluid restrictor so that the calibration
bar graph averages center to right middle. This means
that the "B" dosing valve is open 25% to 75% of the
time.
Ensure dosing valve needle packing nuts are not
adjusted too tight. They should be snug when there is
no fluid pressure on the valve.
If feed pumps are used, don't use more than 250psi
(17 bar). Excess pressure adds double the amount of
pressure on only the upstroke of the XM metering
pump.
312359M
Motor Icing
Air motors accumulate ice in the exhaust valving and
muffler under hot and humid conditions or under cold
ambient conditions. It can cause pressure loss or motor
stalling.
The 'B' fluid pressure should always be 15% to 30%
higher than 'A' pressure.
A larger pressure difference indicates 'A' motor icing.
A smaller or negative pressure difference indicates 'B'
motor icing.
Ensure that the XL motor de-ice bleed valves are open
to bleed warm air across the ice.
Ensure that the motor is left active when not spraying
to keep the internal bleed air working. Leave the motor
active in Spray mode or Manual mode to keep the
bleed air on.
Restrictions or Lost Pressure
Always use filter screens in the XM pump lowers. Filter
style pumps come with 60 mesh screens. Optional 30
mesh elements are also supplied.
Always use a gun filter. 60 mesh is provided in the gun.
Check that the static mixer is clean.
Early mix manifolds (2009) had a 40 mesh screen on
the B side. The screen could plug with materials that
have filled 'B' side fluids.
Troubleshooting
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm50Xm70

Table of Contents