Basic Operation

Basic Operation
Power On (Alternator Power
Supplied Systems)
1. Set main pump air regulator (CD) to minimum
setting.
2. Open main air valve (E) and main pump and air
valve (CA) to start air-powered alternator.
Main air pressure is displayed on gauge (CC). Fluid
Control screen will display after five seconds.
CC
CA
Power On (Wall Power Supplied
Systems)
Turn on main power disconnect. Fluid Control screen
will display after five seconds.

Adjust Ratio and Setup

1. Turn key to right (setup position). Yellow LED will
flash and the Home Setup screen will display.
2. Press
and
3. When desired ratio is displayed, turn key to left.
Yellow LED will turn off.
4. Change optional setup selections to desired
parameters, as described in Set System Settings
(Optional), page 25.
24
CD
CE
to change ratio.

Final Setup

Perform the following steps if shutting down during
setup.
1. Relieve system pressure. See Pressure Relief
Procedure, page 35.
2. Flush and prime system. See Prime (page 28),
Flush Mixed Material (page 37) and Park Fluid
Pump Rods (page 38).
3. Check ratio accuracy. Run Pump and Metering
Test (page 39) and Batch Dispense or Ratio Test
(page 42) to check ratio accuracy.

View Alarms

When an alarm occurs the alarm information screen
automatically displays. It shows the current alarm code
along with a bell icon. It also shows the alarm location
with top and side views of the sprayer
There are two levels of error codes: alarms and
advisories. A bell icon indicates an alarm. A solid bell
icon with an exclamation point and three audible alerts
indicate a alarm. And an outlined hollow bell icon and a
single audible alert indicate an advisory.
Diagnose Alarms
See Alarm Codes and Troubleshooting, page 74, for
causes and solutions to each alarm code.
Clear Alarms
Press
to clear alarms and advisories. Press
to return the run (fluid control) screen.
For more information on alarms and alarm codes, see
LED Diagnostic Information, page 50.