Batch Dispense Or Ratio Test - Graco XM Series Operation

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

System Verification

Batch Dispense or Ratio Test

This test dispenses a calculated volume of each fluid
based on ratio. The two fluids combined equal the batch
size selected.
Follow this procedure to dispense a batch (into one
container) for touch-up work or to verify a ratio setting
(use separate containers for fluids A and B).
Dispense into a container with graduations no greater
than 5% of each component. If the ratio is known by
weight, use a scale for greatest accuracy.
1. Enter the Test Screens (page 63).
2. Select
to run batch dispense test.
3. Adjust dispense amounts from 500 ml to 2000 ml (in
250 ml increments) by pressing
drop-down box. Then press
the desired value. Press
4. Set main pump air regulator (CD) pressure to zero.
Open main pump and air valve (CA). Adjust main
pump air regulator (CD) pressure to 50 psi (0.35
MPa, 3.5 bar).
CA
42
to open the
and
to select
to select that value.
CD
5. Close recirculation valves (AC, AD), mix manifold
valves (AH, AJ), and sampling valves (AE, AF).
.
AC
AE
AH
6. Place a clean container under sampling valve A
(AE).
7. Press
. Pump A light comes on.
8. Dispense fluid A. Slowly open and adjust sampling
valve A (AE) to achieve desired flow. The pump
stops automatically when dispense completes.
Pump A light (DK) turns off, Pump B light (DK) turns
on.
9. Close sampling valve A (AE).
AD
AF
AJ
312359M