Troubleshooting
Remote Mix Manifold Applications
Ensure remote mix manifold outlet kit is installed. See XM
Repair parts manual. The kit includes outlet check valves
which isolate the pump pressure sensors from the outlet
hoses, and includes a 'B' side restrictor valve for the
machine outlet.
Early remote manifold machines didn't include the 'B'
restrictor valve from the factory.
Ensure that the 'A' and 'B' outlet hose sizes volume
balanced close to the mix ratio. Unbalanced hose sizes
can cause off ratio slugs at the mix manifold during
pressure and/or flow transitions. See XM Mix Manifold
Kits manual.

LED Diagnostic Information

The following LED signals, diagnosis, and solutions are the same for the display module, fluid control module, and
USB module. LEDs are located next to the module power cable.
Module Status LED Signal
Green on
Yellow
Red solid
Red flashing fast
Red flashing slow
50
Diagnosis
System is powered up and power supply
voltage is greater than 11 Vdc.
Internal communication in progress
Hardware failure
Uploading software
Token error
If a minimum of integration and mix hose is used,
ensure that "Fast Dosing" is selected in the setup
screens
Software Version
Ensure all modules in the system use software from
same token. Different software versions may not be
compatible.
The latest software version for each system can be
found at Tech Support at www.graco.com.
-
-
Replace display module, fluid
control module, or USB module.
-
Remove token and upload software
token again.
Solution