Appendix C
Appendix C
Power Cord Guidelines
Use the guidelines listed in the following table to determine the power cord needed for your specific system.
XM_A (00, 11, 13,
21, 23, 30-32)
Power Supply
wall
Viscon HP Fluid
N/A
Heaters
Configuration Options:
Controls
1 A, 120 Vac
Viscon HP (2)
N/A
Hopper
Immersion
N/A
Heaters (2)
Viscon HP
with Heat
N/A
Circulation (1)
Electric Hose
N/A
Control (1)
Full Load Peak
Amperes at 240 V,
1 A
1 Phase
2
Cord Specification AWG (mm
) at:
240 V, 1 PH
240 V, 3 PH
N/A
380 V, 3 PH
Wired by user if ordered. Cord size determined by user.
Full load amperes with all components operating at maximum capabilities. Fuse requirements for various flow
rates and heater temperature settings may be less.
72
Table 3: Power Cord Guidelines
XM_A (14-19,
XM_B (all)
24-29)
wall
wall; junction box
N/A
2 heaters
1 A, 120/240 Vac
1 A, 240 Vac
32 A at
N/A
240 Vac,
1 PH
13 A at 240 V,
13 A at 240 V,
1 PH
1 PH
16 A at 240 V,
16 A at 240 V,
1 PH
1 PH
or
or
15 A at 240 V,
15 A at 240 V,
1 PH
1 PH
30 A
62 A
4 (21.2)
2 wire + ground
6 (13.3)
3 wire + ground
6 (13.3)
4 wire + ground
XM_D (00, 11, 13,
XM_C (all)
21, 23, 30-32)
wall
alternator
2 heaters
N/A
1 A, 240 Vac
N/A
32 A at
240 Vac,
N/A
1 PH
13 A at 240 V,
N/A
1 PH
16 A at 240 V,
N/A
1 PH
or
15 A at 240 V,
1 PH
N/A
0 A
62 A
(air only)
N/A
XM_D (17, 19, 27,
XM_E (all)
29)
alternator
alternator
N/A
2 heaters
N/A
N/A
32 A at 240 V,
1 PH (wired by
N/A
user with
explosion proof
methods)
N/A
N/A
16 A at 240 V,
16 A at 240 V,
1 PH (wired by
1 PH (wired by
user with
user with
explosion proof
explosion proof
methods)
methods)
N/A
N/A
16 A
48 A
N/A
N/A
312359M