OPERATING AND ASSEMBLY MANUAL
8.2.6
CLEANING/PAINT CHANGE ON THE PXM WITH ULTRASONIC SIEVE
Notes for the paint change sequence:
The ultrasound sieve can be cleaned either manually or using existing cleaning components.
Three steps are planned:
Coarse cleaning using the internal cleaning program of the IP 5000 fresh powder
pump. The screen frame can remain installed.
Main cleaning with blowout device and compressed air pulses (see Cleaning
Parameters, Chapter 6.9.2). The sieve frame must be replaced with a dummy frame to
avoid damage to the sieve fabric.
Perform a manual fi nal cleaning of the individual components.