1. Switch the system on.
2. Move the reciprocator all the way to the top (reference).
3. Set the powder tank. For boxes, loosen powder beforehand.
4. When feeding from the powder box: Pull the foil over the box rim until it lies fl at on
the box walls.
5. Insert fl uidization and check pressure (start with 0.5 bar setting).
6. Plug the peristaltic pump tube and fresh powder hose onto the loss position.
7. Select the "Automatic" button; the retractor then moves downwards and determines
the powder level.
When using boxes, ensure that the fl uid device moves past the foil and does not
press it down.
If necessary, retighten the foil.
8. Check fl uidization and set if necessary.
When using a fl uid tank, the powder should fl ow like water without generating
larger bubbles.
When using powder boxes, the powder should be fl owable in the fl uid rod area
without generating larger bubbles or dust.
Note: An excessive fl uid air setting leads to a greater loss of powder.
9. Insert tank cover.
10. Plug the fresh powder hose*
11. Start coating.
12. First switch off the peristaltic pump on the touch screen according to an arbitrary
time, plug the hose *
13. For longer breaks and at the end of production, switch to manual mode and move
the suction system from the tank to the top in reverse order.
Attention: Remove the cover fi rst.
14. At the end of production, WAGNER recommends you rough clean the system and
fl ush the injectors, powder hoses and guns (via application controller) and perform
a normal cleaning for the IP 5000 fresh powder pump.
Move the suction device completely up before turning off the system.
Remove tank or box or close with a dummy cover so that no debris can fall into it.
Note: If the PXM is connected to the fi nal fi lter, the throttle valves can only be opened
if no coating is applied.
*
When an automatic fresh powder supply is available
** When using an ultrasonic sieve, plug the fresh powder hose directly onto the
connection on the sieve and the peristaltic pump tube on the feedthrough socket
on the base plate of the powder center
ORDER NUMBER DOC2350372
,
** onto the tank cover.
,
** on the tank cover and switch the peristaltic pump on again.