Machine Parameter Cleaning - WAGNER PXM Operating And Assembly Manual

Powder center
Table of Contents

Advertisement

VERSION 08/2015
OPERATING AND ASSEMBLY MANUAL
6.9.2

MACHINE PARAMETER CLEANING

Interface
Communication with the application controller:
Injectors
Preliminary cleaning Block 1
Number of pulses:
Pulse time:
Break time:
Preliminary cleaning Block 2
Number of pulses:
Pulse time:
Break time:
Cleaning Block 1
Number of pulses:
Pulse time:
Break time:
Cleaning Block 2
Number of pulses:
Pulse time:
Break time:
Dynamics:
FP supply
Pre-cleaning
Number of pulses:
Pulse time:
Break time:
Cleaning
Pulse time:
Break time:
RP supply
Cleaning
Number of pulses:
Pulse time:
Break time:
US sieve
Pre-cleaning
Number of pulses:
Pulse time:
Break time:
Cleaning
Number of pulses:
Pulse time:
Break time:
ORDER NUMBER DOC2350372
No
2
0.2 secs
1 secs
2
0.2 secs
1 secs
8
0.5 secs
2 secs
8
0.5 secs
2 secs
Off
2
0.5 secs
2.0 secs
1.0 secs
2.0 secs
10
1.0 secs
2.0 secs
5
0.2 secs
2.0 secs
5
0.5 secs
2.0 secs
PXM