Technical Data - WAGNER PXM Operating And Assembly Manual

Powder center
Table of Contents

Advertisement

VERSION 08/2015
OPERATING AND ASSEMBLY MANUAL
5.5

TECHNICAL DATA

Dimensions:
Maximum height
Maximum width
Maximum depth
Weight
Electrical:
Three-phase current connection
Frequency
Total power consumption
Protection class
Pneumatic:
Compressed air connection
Cross-section of compressed air line
Compressed air quality
Air throughput coating mode
Air throughput cleaning mode
Suction capacity, exhaust
Filter surface area (version with fi lter)
Number of fi lters
Filter capacity
Permanent suction output for version with connection to a fi nal fi lter: 1,000 Nm3/h; 35,308.34 cf
Equipment:
Exhaust air containing oil!
Risk of poisoning if inhaled.
Number of injectors
Ambient conditions:
Operating temperature range
ORDER NUMBER DOC2350372
2,660 mm; 104.72 inches
2,170 mm; 85.43 inches
1,400 mm; 55.12 inches
Approx. 500 kg + 150 kg fi lter suction
230/400 V 3P/N/PE 50 Hz
50 Hz
1.5 kW (without fi lter)/3.7 kW (with fi lter)
IP 54
0.6 – 0.8 MPa; 6 – 8 bar; 87 – 116 psi
At least 1.5"
6.5.2 according to ISO 8573.1: 2010
45 Nm³/h; 1,588.88 cf/h
100 – 150 Nm3/h in approx. 30 sec.
4,000 m³ at 1,300 Pa; 5,230.86 cubic yards at 0.19 psi
40 m²; 430.55 square foot
2
> 99%
WARNING
Provide compressed air free from oil and water
(Quality Standard 7.5.4 as per ISO 8573.1, 2010)
7.5.4 = 5-10 mg/m³ / ≤7 °C; 44.6 °F / 5 mg/m³.
PXM 20/22: 20 injectors when feeding from the box
PXM 20/22: 22 injectors when feeding from the fl uid tank
PXM 34: 34 injectors when feeding from the fl uid tank
5 – 45 °C; 41 – 113 °F
PXM
24

Hide quick links:

Advertisement

Table of Contents
loading