Mode Of Operation; Protective And Monitoring Equipment - WAGNER PXM Operating And Assembly Manual

Powder center
Table of Contents

Advertisement

VERSION 08/2015
OPERATING AND ASSEMBLY MANUAL
5.2

MODE OF OPERATION

The PXM powder center is a system from which fl uidized powder is conveyed simultaneously
from a powder tank (option) to several spray guns. Powder consumption is compensated
by the fresh powder feed device (option) in the powder center or by manually refi lling.
The linear motion unit suction system is immersed directly into the powder tank.
A homogenous powder/air mixture is created through the fl uidization and vibration
(option) of the tank. The injectors convey the powdered paint to the guns in the coating
system. A lowered powder level in the tank is detected by the level sensor in conjunction
with sensors on the reciprocator. The level sensor also triggers the lowering of the suction
system and the fresh powder supply (option) when necessary. A warning is triggered
automatically in the event of a powder shortage and the warning lamp lights up yellow.
If the minimum level is not reached after a certain time, the alarm lights up red and the
system registers a malfunction. Powder level monitoring is active only in automatic mode.
5.3

PROTECTIVE AND MONITORING EQUIPMENT

Protective and monitoring equipment must not be removed, modifi ed or rendered
unusable.
Regularly check for perfect functioning.
If defects are detected on protective and monitoring equipment, the system must not
be operated until these defects are remedied.
Safety Device
EMERGENCY STOP button
ORDER NUMBER DOC2350372
Eff ect
– Powder feed blocked
– Linear motion unit blocked
– Fluidization and vibrator deactivated
PXM
21