General Safety Instructions; Safety Instructions For The Operator; Electrical Devices And Equipment; Personnel Qualifications - WAGNER PXM Operating And Assembly Manual

Powder center
Table of Contents

Advertisement

VERSION 08/2015
OPERATING AND ASSEMBLY MANUAL
4

GENERAL SAFETY INSTRUCTIONS

4.1

SAFETY INSTRUCTIONS FOR THE OPERATOR

Keep this operating manual on hand near the device at all times.
Always follow local regulations concerning occupational safety and accident prevention.
4.1.1

ELECTRICAL DEVICES AND EQUIPMENT

To be provided in accordance with the local safety requirements with regard to the
operating mode and ambient infl uences.
May only be maintained by skilled electricians.
Must be operated in accordance with the safety regulations and electrotechnical
regulations.
Must be repaired immediately in the event of problems.
Must be decommissioned if they pose a hazard.
Must be de-energized before work is commenced on active parts.
Secure the device against being switched back on without authorization. Inform staff
about planned work.
Observe electrical safety regulations.
4.1.2

PERSONNEL QUALIFICATIONS

Ensure that the device is only operated, maintained and repaired by trained persons.
4.1.3

SAFE WORK ENVIRONMENT

The fl oor in the working area must be electrostatically conductive (measurements
according to EN 1081).
Make sure that all persons within the working area are wearing electrostatic-conductive
shoes.
Ensure that gloves worn are made of conductive material.
The powder release must be electrically interlocked with the powder spray system's
exhaust air equipment.
Excess coating product (overspray) must be collected up safely.
Ensure that there are no ignition sources such as naked fl ames, sparks, glowing wires,
or hot surfaces in the vicinity. Do not smoke.
Maintain suffi cient quantities of suitable fi re extinguishers and ensure that they are
serviceable.
The operating company must ensure that an average concentration of powder lacquer
in the air does not exceed 50% of the lower explosion limit (LEL = max. permitted
concentration of powder to air). If no reliable LEL value is available, the average
concentration must not exceed 10 g/m³.
ORDER NUMBER DOC2350372