VERSION 08/2015
OPERATING AND ASSEMBLY MANUAL
6.9

STANDARD SETTINGS

The most important settings for speedy commissioning of the powder center have already
been carried out by the manufacturer.
You can, however, change standard settings to suit your needs. The changes remain saved
even if the powder center is switched off with the main switch.
The following standard settings are made in the factory.
6.9.1

MACHINE PARAMETERS OPERATION

Workstation
Alarm delay powder shortage:
FP supply
FP station:
FP bigbag:
Bigbag type:
FP redosing time manual:
FP redosing time automatic:
RP supply
RP supply:
Operating mode:
RP feed time:
RP break time:
Message recovery system:
RP supply:
US sieve
US sieve:
After-run time if US sieve available:
Dirt discharge:
After-run time before:
Wait time:
Pulse time:
Break time:
Exhaust system
Exhaust system:
Filter cleaning pulse time:
Filter cleaning break time:
Final fi lter, automatic closing:
ORDER NUMBER DOC2350372
30 sec.
1
1
IP 5000
30 sec.
30 sec.
Yes
Eco
50 sec.
10 sec.
60 sec.
Cycle 1: 2.5 sec.
Cycle 2: 0.3 sec.
Cycle 3: 2.5 sec.
Cycle 4: 0.3 sec.
No
30 sec.
3 pulses
12 sec.
10 min.
1.0 sec.
5.0 sec.
Integrated
0.2 sec.
60 sec.
10 sec.
PXM